Laserfiche WebLink
PIPE CULVERT ANALYSIS <br />C', MUTATION OF CULVERT PERFORMANCE CURVE <br />October 2, 1989 <br />PROGRAM INPUT DATA: <br />DESCRIPTION VALUE <br />Culvert Diameter (feet) ................................. 2.00 <br />FHWA Chart Nur'ber (1,2 or 3) ............................ '' <br />Scale Number on Chart (Type of Culvert Entrance) ........ 3 <br />Manning`s Roughness Coefficient (n- value) ............... 0.0240 <br />Entrance Loss Coefficient of Culvert Opening........ 0.50 <br />Culvert Length ( feet) .... ............................... 106.0 <br />Culvert Slope (feet per foot ) ........................... 0.0500 <br />PROGRAM RESULTS: <br />Flow Tailwater Headwater (ft) Normal Critical Depth at Outlet <br />Rate Depth Inlet Outlet Depth Depth Cutlet Velocity <br />(cfs) (ft) Control Control (ft) (ft) (ft) (fps) <br />- - -w 3.6 1.00 0.96 - 3.84 0.49 0.67 0.49 6.04 <br />---------------------- - - - - -- ------------------------ <br />----------------------------- - <br />PIPE CULVERT ANALYSIS CCMPUTER PROGRAM Version 1.5 Copyright (c)1986 <br />Dodson & Associates, Inc., 7015 W. Tidwell, #107, Houston, TX 77092 <br />(713) 895 -8322. All Rights Reserved. <br />2.05.3- E2.H.359 12/09 <br />