Laserfiche WebLink
RULE 4 PERFORMANCE STANDARDS <br />• 1. Lower Taylor Creek (LTC) represents the water quality conditions of Taylor Creek directly downstream of <br />the South Taylor mining area and immediately prior to the confluence with Wilson Creek and immediately <br />downstream of the Gossard Loadout. <br />2. Lower West Fork Good Spring Creek (LWFGSC) represents this tributary after potential impacts caused by <br />South Taylor mining. <br />3. East Fork Good Spring Creek (EFGSC) represents the upstream, undisturbed background condition of the <br />East Fork Good Spring Creek. <br />4. Upper West Fork Good Spring Creek (UWFGSC) represents the upstream, undisturbed background <br />condition of the West Fork Good Spring Creek. <br />5. New Upper Good Spring Creek (NUGSC) represents the water quality of Good Spring Creek downstream of <br />the confluence of the east and west forks of the creek and downstream of the South Taylor mining area. <br />6. Lower Good Spring Creek (LGSC) represents the water quality downstream of the South Taylor and existing <br />mining areas. <br />Quarterly Surface Water Field Parameters <br />Temperature Flow pH Conductivity <br />Ouarterly Surface Water Laboratorv Parameters <br />Flow pH Conductivity Total Dissolved Total Suspended <br /> Solids Solids <br />Bicarbonate (HC03) Calcium (Ca+) Magnesium (Mg+) Ammonia (NH3) Nitrate-Nitrite <br />Phosphate Sodium (Na') Sulfate (SOO Arsenic (As) Iron - Total <br />PO4 as P) -- I <br />Lead (Pb) Mercury (Hg) Manganese (Mn) <br />r Selenium (Se) Zinc (Zn) <br />Prior to mining at Lower Wilson, the following three surface water monitoring sites will be added to the <br />• sampling schedule: <br />1. Upper Wilson Creek (UWC) represents water quality upstream of all mining impacts. <br />2. Upper Middle Wilson Creek (UMWC) represents water quality downstream of the proposed <br />Lower Wilson mining area. <br />3. Lower Wilson Creek (LWC) represents water quality immediately upstream of the confluence <br />with Taylor Creek. <br />It is reasonable to expect potential future monitoring activities for the Lower Wilson locations to mirror <br />those for the existing operation as it pertains to frequency and specific parameters. <br />Groundwater - Six alluvial groundwater sites will be monitored (Field parameters gathered during Is' <br />through 4th quarters, lab samples taken during 2t,d and 4th quarters only). <br />Monitoring Tyne Monitoring Location Monitoring Fre uenc Quarterly Parameters <br />Alluvial Ground Water Gossard Well' Quarterly See Below <br />Alluvial Ground Water A-6 We112 Quarterly See Below <br />Alluvial Ground Water North Good Spring Well3 Quarterly See Below <br />Alluvial Ground Water MT-95-024 Quarterly See Below <br />Alluvial Ground Water A-75 Quarterly See Below <br />Alluvial Ground Water A-86 Quarterly See Below <br />1. Gossard Well - Located within alluvium beneath the rail loop, this site represents the condition of the <br />alluvial aquifer in the vicinity of the Gossard Coal Loadout Facility. <br />South Taylor/Lower Wilson - Rule 4, Page 18 Revision Date: 3/04/08 <br />Revision No.: TR-70