AraZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Bowie Resources, LLC ACZ Project ID: L67328 <br /> <br />L67328-01 WG239663 Arsenic, extractable (AB-DTPA) M6010B ICP D1 Sample required dilution due to matrix. <br />M6010B ICP DB Sample required dilution due to low bias result. <br />M6010B ICP M2 Matrix spike recovery was low, the recovery of the <br /> associated control sample (LCS or LFB) was acceptable. <br />M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG239552 Boron (saturated paste) M6010B ICP RC For a solid matrix, the matrix duplicate precision <br /> assessment (RPD or RER) exceeded the control limit, <br /> which is attributable to the non-homogeneity of the sample. <br />WG239553 Cadmium, extractable (AB-DTPA) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 1 Ox MDL). <br />Copper, extractable (AB-DTPA) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 1 Ox MDL). <br />Lead, extractable (AB-DTPA) M6010B ICP M2 Matrix spike recovery was low, the recovery of the <br /> associated control sample (LCS or LFB) was acceptable. <br />M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />Manganese, extractable (AB-DTPA) M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br /> because the sample concentration was less than 50 times <br /> the MDL. <br />WG239550 Molybdenum, extractable (NH4 Oxalate) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG239554 Selenium, soluble (Hot Water) SM3500-Se.C RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 1 Ox MDL). <br />WG239553 Zinc, extractable (AB-DTPA) M6010B ICP B1 Target analyte detected in prep / method blank at or above <br /> the method reporting limit. See Case Narrative. <br />M6010B ICP M2 Matrix spike recovery was low, the recovery of the <br /> associated control sample (LCS or LFB) was acceptable. <br />M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br /> because the sample concentration was less than 50 times <br /> the MDL. <br />WG239533 Organic Matter (Ignition @ 400) EPA 600/2-78-054 M3.2.14 RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 1 Ox MDL). <br />WG239405 Sulfur Organic Residual M600/2-78-054 3.2.4 RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />Sulfur Pyritic Sulfide M600/2-78-054 3.2.4 RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />Sulfur Sulfate M600/2-78-054 3.2.4 RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />Sulfur Total M600/2-78-054 3.2.4 RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 1 Ox MDL). <br />Total Sulfur minus Sulfate M600/2-78-054 3.2.4 RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 1 Ox MDL). <br />REPAD.15.06.05.01 <br />L67328: Page 12 of 17