My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-12-21_REVISION - M1980244 (39)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2009-12-21_REVISION - M1980244 (39)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:24 PM
Creation date
12/30/2009 8:55:13 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
12/21/2009
Doc Name
QA Liner Recert- App. K, Tensiometer Certification
From
CC&V
To
DRMS
Type & Sequence
AM9
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />L_J <br />Customer Name: <br />Unit Make 6 Model Number: <br />Tenslometer Serial Number: <br />Device Calibrated: <br />Range: <br />Model No: <br />Serial No: <br />Readout Model No: <br />Readout Serial No: <br />Channel No: <br />Indicatsr reading with no load: <br />Applied Force lbs. <br />2 <br />32 <br />102 <br />162 <br />202 <br />262 <br />302 <br />CALIBRATION CERTIFICATE <br />Lone Star Linin <br />ccura- <br />NAL -2748 <br />8 -Type load call <br />0 - 600 ibs, Tension <br />M2300.6 -0 <br />218143 <br />DPM -3 <br />222878 <br />N/A <br />...�_ <br />Output (mv): Display reading: <br />0,388 <br />2.473 <br />4.66 <br />8.842 <br />8.723 <br />10.608 <br />12.84 <br />110 volt X <br />220 Volt <br />lbs. X <br />K9• <br />Calibration Apparatus: <br />Dead Weight system w/ <br />Fluke Model 187 Muttlmeter <br />W1 NIA R1 A <br />W2 N/A R2 N/A <br />W3 A Rg /A <br />Deviation Error: <br />Total Deviation Error (%): I FOR <br />Temperature at time of calibration: 73 degrees F <br />Exitation Voltage: 10 V DC <br />Scale Factor (1): N/A Offset (1): NI <br />Scale Factor (2): N/A Offset (2): N/A <br />Brake point: N/A Calibration Check * <br />This calibration Conforms to the standards set by ASTM E4 and Is traceable to NISI standards <br />Note: Readout and load cell above have been systems calibrated and are considered a <br />_ Hatched air. In general, calibrated readouts and load cans are not Interchangeable. <br />Calibrated by: Jeff Hicks , / r <br />Date: 11/02109 <br />F <br />L--.j <br />
The URL can be used to link to this page
Your browser does not support the video tag.