My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-12-21_REVISION - M1980244 (32)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2009-12-21_REVISION - M1980244 (32)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:24 PM
Creation date
12/30/2009 8:54:55 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
12/21/2009
Doc Name
QA Liner Recert- App. E, Tech Specs. 2
From
CC&V
To
DRMS
Type & Sequence
AM9
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
amec <br />D. The following procedures shall apply to locations where seams cannot be non - destructively tested, <br />as determined by CERTIFYING ENGINEER: <br />1. If the seam is accessible to testing equipment prior to final installation, the seam shall be <br />non - destructively tested prior to final installation. <br />2. If the seam cannot be tested prior to final installation, the seaming operations shall be <br />observed by CQA Monitor for uniformity and completeness. <br />E. In the event that seam continuity cannot be demonstrated for a non - destructive test of a fusion <br />seam as outlined above, the CONTRACTOR shall perform the non - destructive testing over <br />smaller areas as a means of defining the questionable area, and shall: <br />Extrusion weld the outside edge of the questionable seam area and vacuum box test the <br />extrusion weld; or, <br />2. Cap the questionable area and vacuum test the cap. <br />3.09 DESTRUCTIVE TESTING <br />A. CONTRACTOR shall test a minimum of one destructive test sample per five hundred (500) feet <br />of seam length from a location specified by CERTIFYING ENGINEER. CONTRACTOR shall <br />not be informed in advance of the sample location. The samples shall be taken centered over the <br />seam and prioritized as follows: <br />1. A minimum of one sample per day; <br />2. All areas identified as suspect during seaming, non - destructive testing/monitoring, and in <br />unusual working conditions. <br />3. A minimum of one sample for each geomembrane seamer. <br />4. A minimum of one sample every five hundred (500) feet of seaming. <br />B. Samples shall be cut by CONTRACTOR as the seaming progresses. Sampling locations shall be <br />determined by CERTIFYING ENGINEER. CQA Monitor must witness the obtainment of all <br />destructive test samples by CONTRACTOR. CONTRACTOR shall mark all samples with their <br />seam number, date, welding machine number, welding technician identification, extruder and <br />nozzle /wedge temperature, and ambient air temperature. CONTRACTOR shall document the <br />date, time, roll and seam number, ambient temperature, and pass or fail description. All holes in <br />the geomembrane resulting from obtaining the seam samples shall be immediately repaired. All <br />patches shall be vacuum tested. <br />C. The samples shall be a minimum twelve (12) inches wide by twenty -four (24) inches long with the <br />seam centered lengthwise. The sample shall be cut into two equal length pieces, half to be given to <br />CC &V and the other half kept by CONTRACTOR. <br />D. CONTRACTOR shall cut and test ten (10) one (1) inch wide specimens from his sample. All <br />testing shall be conducted at room temperature (60° F - 80° F) CONTRACTOR shall test five (5) <br />specimens for seam shear strength and five (5) for peel strength. Both inside and outside tracks of <br />fusion seams will be tested for peel strength. To be acceptable, four (4) out of the five (5) <br />specimens must pass according to criteria established in Article 2.01. Any specimen that fails <br />Section 02776 Page 19 of 22 September 3, 2008 <br />Geomembrane Revision 1 <br />SAProjects \1125E CCV CQA \I - Tech Specs \02776.0.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.