My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-12-21_REVISION - M1980244 (29)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2009-12-21_REVISION - M1980244 (29)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:24 PM
Creation date
12/30/2009 8:53:06 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
12/21/2009
Doc Name
QA Liner Recert- App. A-K, Geomembrane Installation Observations
From
CC&V
To
DRMS
Type & Sequence
AM9
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sent by: 53082227114 <br />05/09/02 11:04 ,lob 430 Page 2/3 <br />A PtastlE' ;4%el "fetftriol <br />1 a T r R a A 1 1 0 N • L <br />CALIBRATION CERTIFICATE <br />Customer Name: POLY -Fxxot 110 VoR ❑X <br />Tensiometer Serial Number. NAL • 0002 220 Volt LJ <br />LBS <br />Device Calibrated: S -Type bad can Calibration Apparatus: <br />Range: 0-500 Its. Tension Dead Weight system w/ <br />Model No: M2300 -500 Fluke Model 8840A Mugimeter <br />Sena] No: _ 164272 <br />W1 2 RI 4 <br />Readout Model No: 2840AG•24123 W2 152 R2 1996 <br />Readout Serial No: 0420992-10 W3 302 R3 3989 <br />Channel N0: 1 0 <br />Indicator herding with no load F0 <br />Applied Fonx ms. Output (mv): Display reeding: Deviation Error <br />2 F - 0 - 01 - 6 - 1 2 0 -� <br />52 X2�D 102 162 202 252 302 302 0.00 <br />Total Deviation Error ( %): <br />Temperature at time of calibration: 73 degrees F <br />Exilation Voltage: 10 V DC <br />Scale Factor (1): 0.0762 Olfet(1): <br />Scale Factor (2): 0.0753 Offset (2): 1 <br />Break point: 1998 Calibration Checkf 276 <br />Traceable M NIST 5137 - 1rds <br />•NOTE: Read." ano :oed w0 above have been systems calibrated and am <br />.... rad a matched pair. in general, calibrated readouts and <br />load calb ere not IMI.m si.able. <br />This calibration conform. to the aLndarda set by ASTM E4. <br />,_:..::anon performed b BILL AULTZ <br />Signature: .. %-��.! Date: 425!02 <br />6125 Enterprise Drive. 0110 '--' Ph: WO) 6222791 <br />Diamond Springs CA 95619 Fax(530)627-2704 <br />. 800635-6693 wvaw.plasttc eldlrgtechnologiesxom <br />
The URL can be used to link to this page
Your browser does not support the video tag.