Laserfiche WebLink
SEDCAD 4 for Windows <br />r -...inld 400P _9nn7 D-1 I C..L...,o/. <br />21 <br />• <br />Left Right Freeboard Freeboard Freeboard <br />Sideslope Sideslope Slope (%) Manning's n Mult. x <br />Ratio Ratio Depth (ft) % of Depth (VxD) <br />2.0:1 2.0:1 3.0 0.0170 0.30 <br />Nonerodible Channel Results: <br /> w/o Freeboard w/ Freeboard <br />Design Discharge: 0.63 cfs <br />Depth: 0.29 ft 0.59 ft <br />Top Width: 1.14 ft 2.34 ft <br />Velocity: 3.85 fps <br />X-Section Area: 0.16 sq ft <br />Hydraulic Radius: 0.128 ft <br />Froude Number: 1.80 <br />• <br />Structure #6 (Culvert) <br />C3-1A <br />Culvert Inputs: <br />Culvert Results: <br />Design Discharge = 10.92 cfs <br />Minimum pipe diameter: 1 - 24 inch pipe(s) required <br />Structure #5 (Culvert, <br />C3-ID <br />Culvert Inputs: <br />Max. Tailwater Entrance <br />Length (ft) Slope (%) Manning's n Headwater ft Loss Coef. <br />(ft) () (Ke) <br />260.00 3.00 0.0120 3.00 0.00 0.90 <br /> <br />Culvert Results: <br />Max. Tailwater Entrance <br />Length (ft) Slope (%) Manning's n Headwater ft Loss Coef. <br />(ft) () (Ke) <br />71.00 5.00 0.0240 2.00 0.00 0.90 <br />Design Discharge = 1.43 cfs <br />Minimum pipe diameter: 1 - 8 inch pipe(s) required <br />Structure #4 (Erodible Channel) <br />D3-1 <br />Triangular Erodible Channel Inputs: <br />Filename: MB-3(Rev_spillway).sc4 <br />Printed 08-11-2009