amec0 <br />• PART 3: EXECUTION <br />3.01 INSTALLATION <br />A. Install according to manufacturer's recommendations. <br />B. Pipe shall be unloaded and handled with reasonable care to prevent damage. <br />C. Circumferential seams shall be installed with their inside circumferential sheet laps pointing <br />downstream. <br />D. The completed trench bottom shall be firm for its full length and width or as approved by <br />CERTIFYING ENGINEER. <br />3.02 FIELD CONNECTIONS <br />A. All connections for CSP shall be corrugated bands or other equally effective types of field joints as <br />approved by the CERTIFYING ENGINEER. <br />3.03 BEDDING AND BACKFILL <br />A. Backfill and compact Pipe Bedding Material in accordance with Section 02200.0. <br />3.04 THRUST BLOCKS <br />0 Thrust blocks shall be lean concrete without reinforcement placed as shown on the DRAWINGS. <br />*** END OF SECTION *** <br />r? <br />Section 02711 Page 2 of 2 September 3, 2008 <br />Corrugated Steel Pipe Revision 1 <br />SAProiects\1125 CC&V Phase 5 VLF\I - Tech Specs\Arequa IFC Specs\02711.r1.doc