Laserfiche WebLink
RELATIVE COMPACTION TEST RESULTS <br />PROJECT: West Elk Refuse Pile Expansion <br />PROJECT NO: M09011MT <br />DATE: Friday, Apr/20/09 <br />SITE LOCATION: Somerset <br />CLIENT: Mountain Coal Company <br />ENGINEERING TECHNICIAN: Hayes <br />NUCLEAR GAUGE USED: 18 <br />Laboratory # 1445 <br /> <br /> <br />TEST <br />NO <br /> <br />TESL' LOCATION <br />DEPTH OR <br />ELEVATION <br />PROBE. <br />DEPTH <br />IN LABORATORY <br />PROCTOR <br />DENSITY <br />PCF OPTIMUM <br />MOISTURE <br />CONTENT <br />% <br />DRY <br />DENSITY <br />PCF <br />MOISTURE <br />CONTENT <br />% <br />RELATIVE <br />COMPACTION <br />SOIL TYPE <br />129 RPE-0 1 6154.54 8 80.0 14.0 83.3 14.8 100 Coal Gob, Black <br />130 RPE-02 6156.62 8 80.0 14.0 80.4 15.0 100 " " <br />131 RPE-03 6157.32 8 80.0 14.0 79.5 15.3 99 " " <br />132 RPE-04 6160.73 8 80.0 14.0 85.7 14.3 100 " " <br />133 RPE-05 6159.24 8 80.0 14'0 88.5 13.7 100 " " <br />134 RPE-06 6161.76 8 80.0 14.0 85.1 9.4 100 " <br />REMARKS: The test results indicate only the density and moisture content for the location and elevation tested only. <br />PROJECT NUMBER: M09011MT