Laserfiche WebLink
MINREC,INC. ANNUAL HYDROLOGIC REPORT PAGE 6 <br /> METHODS <br /> The following narrative explains the methods used to perform water monitoring: <br /> Flow- Flow is determined at discharge points by timing flow into a bucket of known volume. <br /> pH - A Cole Parmer pocket size tester (pH. Range -1.0 to 15.0 pH). Resolution 0.1 pH. <br /> Accuracy +/- 0.1 pH. Operating temperature 0 to 50 °C. Temperature compensation: <br /> automatic 0 to 50 °C. <br /> Conductivity - One Cole Parmer TDS Testr 20 pocket size tester. Accuracy: +/- 2% FS. <br /> Temperature compensation: automatic 0 to 50 °C. Operating temperature: 0 to 50 °C. <br /> Ranges: 0 to 0 to 1,900 umhos/cm and 2.0 to 19.90 mmhos/cm. <br /> Depth to Water - A Water Level Indicator (M-Scope) is used to measure depth to water. <br /> The cable is marked in 5-foot increments. A tape measure is used to determine accurate <br /> distances between marked increments. <br /> Temperature -A standard mercury thermometer which measures temperature in degrees <br /> Celsius or a microprocessor based pocket sized temperature tester is used. <br /> Other parameters-Samples are submitted in bottles to either Grand Junction Laboratories <br /> or SOLTESCO. <br />