Laserfiche WebLink
GATE <br />RELOCATION <br />(SEE DETAIL <br />?A SHEET6OF6) <br />I I I <br />II I WCUTTOP <br />12" <br /> <br />#4 @ 6" O.C. ALL <br />AROUND <br />12" <br />112" J 1-- 9". <br />B"ABOVE CONCRETE <br />PIPE, 12" BELOW & <br />ON SIDES OF <br />CONCRETE PIPE <br />FROM BOX 13.3'(SEE NOTE 4) <br />I I CULVERT,PPJNT <br />I I EXPOSED REBAR <br />F_ rp=rZ7 =rC1==ru=rm=1 <br />? 10' I I I I <br />I <br />II I I <br />II I r <br />II I I <br />II I I <br />II ( I <br />II I <br />i a <br />II I i <br />------ -- --------- - t- <br />g" <br />- - - - - - - - - - - - - - - - - <br />-4.0'+/- MIN <br />I I / <br />3' I I I <br />I I I <br />I I i I / <br />pppl / <br />SLURRY WALL q <br />RELOCATED GATE VAULT PROFILE 1 <br />0 2 4 <br />BACKFILLTO <br />Scale In Feet EXISTING GRADE <br />3" MIN CUR <br />#6 DOWELS <br />-FIVE IN FLOOR & CEILING- <br />THREE IN WALLS <br />ROUGHEN SURFACE PRIOR TO <br />CONCRETE PLACEMENT <br />HYDROPHILIC WATER <br />STOP ALL AROUND <br />(EARTH SHIELD TYPE 20 <br />OR APPROVED EQUAL) <br /> <br />1 <br />-GRATING SUPPORT (SEE <br />0• P <br />GRATE ANCHORING DETAIL) I <br />- <br />?_SAWCUTTOPFROM I - <br />BOXCULVERT <br />3 ' <br />i <br />%"0 HOLE <br />5" DEEP <br />! I <br /> /' • • • <br />1"0 HOLE <br />i <br /> NOTES: __-- ___ -_--L-- <br /> " ° 1. CONCRETE4000psi PER CDOT FLUME SECTIONA A' <br />i VARIES <br />15 15 SPECS <br />0 2. SET DOWELS IN DRILLED HOLE 0 1 2 <br />d COLLAR DETAIL WITH TWO PART EXPOXY <br />0 3. STRUCTURE DIMENSIONS AND Scale In Feet <br />0 1 2 STEEL CONFIGURATIONS OF y <br />P??1 EXISTING STRUCTURES BASED <br />Scale In Fee ON DESIGN PLANS BY MULLER <br /> ENGINEERING DATED FEB 2005. <br /> 4. SHORTEN 20' PIECE TO 13.3' TO <br /> ALLOW FOR COLLARS. <br />F-*'-A' <br />i STYLE'C' PORCELAIN <br />12" 6" ENAMELED STAFF GAGE <br />OVERLAP <br />° <br />4 ° I <br />a <br />3 ° a <br />B"f 'CLR ° 3"CLR <br />& L 1'CLR <br />° 1.25' ? <br />a <br />° <br />#4 <br />#4 @ 12" O.C. 3" CUR <br />FROM <br />DIVERSION <br />STRUCTURE <br />------ 2.50' <br />3.5' - 3.5' 2.5' <br />DRILL HOLE AT INVERT OF <br />e EXISTING BDX AND INSERT <br />1"O PVC TUBE. SEALTUBE <br />° 4 c \ IN DRILL HOLE WITH <br />SILICONE CAULKING <br />d <br />%"0 HOLE <br />5"DEEP I < ° <br />27" --?F? 15" <br />A SALVAGE STILLING <br />FLUME PLAN WELLAND RECORDER <br />BOX FROM STA 0~14.2. <br />CONCRETE PLUG AT <br />BOTTOM OF STILLING <br />WELL TO PROVIDE <br />STILLINGWELL DEPTH <br />OF 9" OR MORE BELOW <br />FLUME INVERT. <br />5/e"0 HOLE <br />5" DEEP <br /> <br /> <br />SECURE BOLT <br />WITH ANCHOR 5" MIN. <br />BOLT & CLIP <br /> VARIES B" TO 10" <br />GRATE ANCHORING DETAIL <br /> 0 3' 6" <br /> Scale In Inches <br />FLUME PROFILE <br />D 1 2 <br />Scale In Feet <br />DRAFiI