Laserfiche WebLink
are expected to be satisfied in all cases. It is also expected that the average reading in the <br />occupied space of each truck cab will not exceed the DOT limit of 2 mrem/hr, specified in 49 <br />CFR 173.441(b)(4). <br />8.2. <br />It is the responsibility of the Mine operat:owner to ensure that the radiation levels fall within <br />the applicable limits summarized in Secti n 8.1 above At a minimum, the Mine operator/owner <br />will perform the following surveys at the; Mine site on a representative number of uranium ore <br />shipments from the Mine: <br />a) A beta/gamma survey will be con ucted at various locations on all sides of the transport <br />vehicle to determine if the radiation level exceeds 200 mrem/hr at any point on the <br />external surface of the vehicle; <br />b) A gamma survey will be conduct d at one meter from all sides of the transport trailer. <br />The average reading in mrem/hr ill be recorded as the Transport Index for all uranium <br />ore shipments from the Mine; and. <br />c) A gamma survey will be conduct d within the cab of the transport tractor. The average <br />reading in mrem/hr will be record. d to verify that the occupied space will not exceed the <br />2 mrem/hr limit. <br />These surveys will be recorded and kept o4 file. <br />In addition, the Mine operator/owner will perform (and document for the record) spot gamma <br />surveys on uranium ore shipments from time to time as it deems appropriate in order to ensure <br />that the regulatory standards are satisfied. <br />8.3. Removable Contamination Surveys <br />8.3.1. Vehicles Used Solely for Purposes o6 Transporting Ore from the Mine to the Mill. <br />49 CFR 177.843 provides that routine surface contamination surveys are not required at the Mine <br />site or at the Mill for any vehicle used solely for transporting bulk-unpackaged uranium ore from <br />the Mine to the Mill provided that: <br />a) a survey of the interior surface <br />radiation dose rate does not exce <br />the interior surface. Since the cc <br />to exceed 2mrem/hr on contact, <br />other point on an empty trailer) s <br />b) the vehicles are stenciled with <br />ONLY" as described under Sec <br />the conveyance trailer (when empty) shows that the <br />10 mrem/hr on contact or 2 mrem/hr at 1 meter from <br />eyance, when filled with uranium ore is not expected <br />surveyed dose rate from the interior surface (or any <br />not exceed these limitations; <br />words "FOR RADIOACTIVE MATERIALS USE <br />4(b) above; and <br />0 <br />0 <br />• <br />July 5, 2007 8 Rev 0