Laserfiche WebLink
fingivoT ENERGYLABORATOR/ES, /NC. • 2351? Sall Creek Highway (826011 P.O. Box 3258 • Casper WY 82602 <br />To// Free 8882350515 • 307235.0515 • Fax 307.234.1639 • Casper energylab.com • www.energylab.com <br />CLIENT: Denison Mines (USA) Corp Date: 30-Jan-09 <br />is Project: Sunday Mines Attenuation Tests - 68838 CASE NARRATIVE <br />Sample Delivery Group: C09010103 <br />ORIGINAL SAMPLE SUBMITTAL(S) <br />AU original sample submittals have been returned with the data package. <br />SAMPLE TEMPERATURE COMPLIANCE: 4°C (t2°C) <br />Temperature of samples received may not be considered properly preserved by accepted standards. Samples that are hand <br />delivered immediately after collection shall be considered acceptable if there is evidence that the chilling process has begun. <br />GROSS ALPHA ANALYSIS <br />Method 800.0 for gross alpha and gross beta is intended as a drinking water method for low TDS waters. Data provided by <br />this method for non potable waters should be viewed as inconsistent. <br />RADON IN AIR ANALYSIS <br />The desired exposure time is 48 hours (2 days). The time delay in returning the canister to the laboratory for processing <br />should be as short as possible to avoid excessive decay. Maximum recommended delay between end of exposure to <br />beginning of counting should not exceed 8 days. <br />SOILISOLID SAMPLES <br />All samples reported on an as received basis unless otherwise indicated. <br />ATRAZINE, SIMAZINE AND PCB ANALYSIS USING EPA 505 <br />Data for Atrazine and Simazine are reported from EPA 525.2. not from EPA 505. Data reported by ELI using EPA method <br />505 reflects the results for seven individual Aroclors. When the results for all seven are ND (not detected), the sample <br />meets EPA compliance criteria for PCB monitoring. <br />SUBCONTRACTING ANALYSIS <br />Subcontracting of sample analyses to an outside laboratory may be required. If so, ENERGY LABORATORIES will utilize its <br />branch laboratories or qualified contract laboratories for this service. Any such laboratories will be indicated within the <br />• Laboratory Analytical Report. <br />BRANCH LABORATORY LOCATIONS <br />eli•b - Energy Laboratories, Inc. - Billings, MT <br />eli-g - Energy Laboratories, Inc. - Gillette, WY <br />eli-h - Energy Laboratories, Inc. - Helena, MT <br />eli-r - Energy Laboratories, Inc. - Rapid City, SD <br />eli-t - Energy Laboratories, Inc. - College Station, TX <br />CERTFICATIONS: <br />USEPA: WY00002; FL-DOH NELAC: E87641; California: 02118CA <br />Oregon: WY200001; Utah: 3072350515; Virginia: 00057; Washington: C1903 <br />ISO 17025 DISCLAIMER: <br />The results of this Analytical Report relate only to the items submitted for analysis. <br />ENERGY LABORATORIES, INC. - CASPER,WY certifies that certain method selections contained in this report most <br />requirements as set forth by the above accrediting authorities. Some results requested by the client may not be covered <br />under these certifications. AD analysis data to be submitted for regulatory enforcement should be certified in the sample <br />state of origin. Please verify ELI's certification coverage by visiting www.energylab.com <br />ELI appreciates the opportunity to provide you with this analytical service. For additional information and services visit our <br />web page www.energy[ab.com. <br />THIS IS THE FINAL PAGE OF THE LABORATORY ANALYTICAL REPORT <br />•