Laserfiche WebLink
Table 2 (Continued) <br />Development Rock, Ore, and Soil Sample Collection and Analysis Information <br />• <br />Analyte Method <br />Same tainer' <br />Con <br />Preservative <br />Holding Times <br />Limit (v /L 2 <br />Nitrate EPA 353.2 Cool to 4°C 28 days 50 <br /> 500 mL (t 2°C)4 <br />Nitrite EPA 353.3 Plastic bottle H2SO4 to pH 48 hours 100 <br />Ammonia EPA 350.3 <2 28 days 30 <br />Hardness SM 2340C Cool to 4°C 180 days NA <br />Aluminum - Total Recoverable EPA 200.8/200.7 500 ML (t 2°C)4 180 days _ <br />100 <br />Iron - Total Recoverable EPA 200.8/200.7 Plastic bottle HN03 to 180 days 30 <br />Mercury - Total Recoverable EPA 245.1 pH<2 28 days 1 <br />MWW Lmm ha% Warr <br />Aluminum EPA 200.8/200.7 100 <br />Antimony EPA 200.8/200.7 1 <br />Arsenic EPA 200.8/200.7 Cool to 4°C 1 <br />Barium EPA 200.8/200.7 500 ML (t 2°C), 1 <br />Beryllium EPA 200.81200.7 Plastic <br /> <br /> <br />bottle HN03 t <br /> <br />o <br />pH<2 <br />0 <br />45 <br /> <br />180 days <br /> <br />1 <br />Boron EPA 200.8/200.7 , <br />. <br />Nm filtration <br />100 <br />Cadmium EPA 200.8/200.7 1 <br />Chromium EPA 200.8/200.7 1 <br />Cobalt EPA 200.8/200.7 1 <br />Copper EPA 200.8/200.7 1 <br />Iron EPA 200.8/200.7 30 <br />Lead EPA 200.8/200.7 500 mL 1 <br />Lithium EPA 200.8/200.7 Plastic 100 <br />Manganese EPA 200.8/200.7 bottle <br />(same ° <br />Cool to 4 C 1 <br />Mercury EPA 245.1 bottle as (t 2°C)4 1 <br />Molybdenum EPA 200.8/200.7 all other HN03 to 180 days 1 <br />Nickel EPA 200.8/200.7 dissolved PH<2, 0.45 1 <br />Selenium EPA 200.8/200.7 metals and pm filtration 1 <br /> <br />Silver <br />EPA 200.8/200.7 metalloids <br />listed <br />1 <br />Thallium EPA 200.8/200.7 above) 1 <br />Uranium EPA 200.8/200.7 1 <br />Vanadium EPA 200.8/200.7 1 <br />Zinc EPA 200.8/200.7 1 <br />Notes: <br />'Sample container requirements shown for leachate samples are applicable to field collected water samples, based on the <br />approximate volumes needed to complete the listed analyses for a particular preservative type. Actual container sizes used during <br />the MWMP tests will be determined by the laboratory. <br />2Units in pg/L, unless otherwise noted. <br />3Acid-Base Accounting consists of reporting the following parameters: <br />-Total Sulfur -Residual Sulfur <br />-Water - Extractable Sulfur -Acid Potential <br />-HCl - Extractable Sulfur -Neutralization Potential <br />-HN03 - Extractable Sulfur -Net Acid Generating Potential (NAG or static peroxide test) <br />°NA = not applicable. <br />5Analysis should be performed as soon as possible, or immediately after sample collection. <br />eReporting limit will be spec to the electrode instrument utilized by the laboratory. <br />'Radiochemistry samples have a sample specific Minimal Detectable Concentration (MDC) calculated as the reporting limit. The <br />MDC is affected by counting time, sample volume, TDS concentration, and instrument background. <br />