Laserfiche WebLink
0, Water Surface: None <br />Material: 80-mil/Soil Liner <br />Strength Type: Mohr-Coulomb <br />Unit Weight: 120 Ib/ft3 <br />Cohesion: 1 psf <br />Friction Angle: 18 degrees <br />Water Surface: None <br />Material: Structural Fill <br />Strength Type: Mohr-Coulomb <br />Unit Weight: 120 Ib/ft3 <br />Cohesion: 1 psf <br />Friction Angle: 35 degrees <br />Water Surface: None <br />Global Minimums <br />Method: soencer <br />FS: 1.450290 <br />Center: 243.125, 1890.945 <br />Radius: 1790.224 <br />Left Slip Surface Endpoint: 229.213, 100.775 <br />Right Slip Surface Endpoint: 1665.221, 803.496 <br />Resisting Moment= 1.69803e+010 lb-ft <br />Driving Moment=1.17082e+010 lb-ft <br />Resisting Horizontal Force=8.21407e+006 lb <br />Driving Horizontal Force=5.66374e+006 lb <br />s Valid / Invalid Surfaces <br />Method: soencer <br />Number of Valid Surfaces: 768 <br />Number of Invalid Surfaces: 4083 <br />Error Codes: <br />Error Code -101 reported for 30 surfaces <br />Error Code -103 reported for 49 surfaces <br />Error Code -1000 reported for 4004 surfaces <br />Error Codes <br />The following errors were encountered during the computation: <br />-101 = Only one (or zero) <br />surface / slope intersections. <br />-103 = Two surface / slope intersections, <br />but one or more surface / nonslope external polygon <br />intersections lie between them. This usually occurs <br />when the slip surface extends past the bottom of the <br />soil region, but may also occur on a benched <br />slope model with two sets of Slope Limits. <br />-1000 = No valid slip surfaces are generated <br />at a grid center. Unable to draw a surface. <br />lie