Laserfiche WebLink
Unit Weight: 120 Ib/ft3 <br />Cohesion: 1 psf <br />Friction Angle: 26 degrees <br />Water Surface: None <br />Material: Ph III Geomembrane/Soil Liner <br />Strength Type: Mohr-Coulomb <br />Unit Weight: 120 Ib/ft3 <br />Cohesion: 1 psf <br />Friction Angle: 18 degrees <br />Water Surface: None <br />Material: Ph II Geomembrane/Soil Liner <br />Strength Type: Mohr-Coulomb <br />Unit Weight: 120 Ib/ft3 <br />Cohesion: 1600 psf <br />Friction Angle: 15 degrees <br />Water Surface: None <br />Global Minimums <br />Method: spencer <br />FS: 1.775840 <br />Axis Location: 339.059, 2298.836 <br />Left Slip Surface Endpoint: 199.829, 270.652 <br />Right Slip Surface Endpoint: 1878.068, 970.542 <br />Resisting Moment=3.96273e+010 lb-ft <br />Driving Moment=2.23146e+010 lb-ft <br />Resisting Horizontal Force=1.67501 a+007 lb <br />Driving Horizontal Force=9.4322e+006 lb <br />Valid / Invalid Surfaces <br />Method: spencer <br />Number of Valid Surfaces: 763 <br />Number of Invalid Surfaces: 4237 <br />Error Codes: <br />Error Code -108 reported for 3300 surfaces <br />Error Code -110 reported for 8 surfaces <br />Error Code -111 reported for 929 surfaces <br />Error Codes <br />The following errors were encountered during the computation: <br />-1108 = Total driving moment <br />or total driving force < 0.1. This is to <br />limit the calculation of extremely high safety <br />factors if the driving force is very small <br />(0.1 is an arbitrary number). <br />-1110 = The water table or a piezoline <br />does not span the slip region for a given slip <br />surface, when Water Surfaces is specified as <br />the method of pore pressure calculation. If this <br />tO error occurs, check that the water table or <br />t