Laserfiche WebLink
Unit Weight: 120 Ib/ft3 <br />Cohesion: 1 psf <br />Friction Angle: 26 degrees <br />Water Surface: None <br />Material: Ph V Geomembrane/Soil Liner <br />Strength Type: Mohr-Coulomb <br />Unit Weight: 120 Ib/ft3 <br />Cohesion: 1 psf <br />Friction Angle: 18 degrees <br />Water Surface: None <br />Material: Structural Fill <br />Strength Type: Mohr-Coulomb <br />Unit Weight: 120 Ib/ft3 <br />Cohesion: 1 psf <br />Friction Angle: 38 degrees <br />Water Surface: None <br />Global Minimums <br />Method: spencer <br />FS: 1.506580 <br />Axis Location: 184.320, 1438.365 <br />Left Slip Surface Endpoint: 210.846, 149.065 <br />Right Slip Surface Endpoint: 1231.676, 686.005 <br />Resisting Moment=7.26663e+009 lb-ft <br />Driving Moment=4.82325e+009 lb-ft <br />Resisting Horizontal Force=5.02786e+006 lb <br />01, Driving Horizontal Force=3.33725e+006 lb <br />Valid / Invalid Surfaces <br />Method: spencer <br />Number of Valid Surfaces: 2596 <br />Number of Invalid Surfaces: 2404 <br />Error Codes: <br />Error Code -108 reported for 1835 surfaces <br />Error Code -111 reported for 569 surfaces <br />Error Codes <br />The following errors were encountered during the computation: <br />-108 = Total driving moment <br />or total driving force < 0.1. This is to <br />limit the calculation of extremely high safety <br />factors if the driving force is very small <br />(0.1 is an arbitrary number). <br />-111 = safety factor equation did not converge <br />List of All Coordinates <br />I Material Boundary <br />"0