Laserfiche WebLink
RELATIVE COMPACTION TEST RESULTS <br />PROJECT: West Elk Refuse Pile Expansion <br />PROJECT NO: M09011MT <br />DATE: Friday, Feb/20/09 <br />SITE LOCATION: Somerset <br />CLIENT: Mountain Coal Company <br />ENGINEERING TECHNICIAN: Hayes <br />NUCLEAR GAUGE USED: 18 <br /> <br /> <br />TEST <br />NO <br /> <br />TEST LOCATION <br />DEPTH OR <br />ELEVATION <br />PROBE <br />DEPTH <br />IN LABORATORY <br />PROCTOR <br />DENSITY <br />PCF OPTIMUM <br />MOISTURE <br />CONTENT <br />% <br />DRY <br />DENSITY <br />PCF <br />MOISTURE <br />CONTENT <br />RELATIVE <br />COMPACTION <br />SOIL TYPE <br />16 Retest of #15, Feb/9/09 6148.11 8 103.0 11.5 101.2 12.5 98 Coal Gob, Black <br />17 Retest of #8, Feb/5/09 6163.52 8 106.0 10.0 97.7 13.3 92 44 <br />" <br />18 Retest of #9, Feb/5/09 6166.31 8 106.0 10.0 97.1 10.2 92 46 <br />" <br />19 At RPE-05, Feb/18/09, stake 6158.89 8 106.0 10.0 99.0 13.8 93 44 <br />" <br /> #21 <br />20 At RPE-03, Feb/20/09, stake 6163.94 8 106.0 10.0 98.1 9.8 93 44 <br />" <br /> #23 <br />21 At RPE-04, Feb/20/09, stake 6165.77 8 106.0 10.0 99.4 8.7 94 " <br /> #24 <br />22 At RPE-05, Feb/20/09, stake 6166.07 8 106.0 10.0 98.6 11.0 93 " <br /> #25 <br />REMARKS: The test results indicate only the density and moisture content for the location and elevation tested only. <br />,'?? • <br />',& de 021 PROJECT NUMBER: M09011MT