Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Report Header Expla' on s <br />Batch A distinct set of samples analyzed at a specific time <br />Found Value of the QC Type of interest <br />Limit Upper limit for RPD, in %. <br />Lower Lower Recovery Limit, in % (except for LCSS, mg/Kg) <br />MDL Method Detection Limit. Same as Minimum Reporting Limit. Allows for instrument and annual fluctuations. <br />PCN/SCN A number assigned to reagents/standards to trace to the manufacturer's certificate of analysis <br />PQL Practical Quantitation Limit, typically 5 times the MDL. <br />OC True Value of the Control Sample or the amount added to the Spike <br />Rec Amount of the true value or spike added recovered, in % (except for LCSS, mg/Kg) <br />RPD Relative Percent Difference, calculation used for Duplicate QC Types <br />Upper Upper Recovery Limit, in % (except for LCSS, mg/Kg) <br />Sample Value of the Sample of interest <br />AS Analytical Spike (Post Digestion) LCSWD Laboratory Control Sample - Water Duplicate <br />ASD Analytical Spike (Post Digestion) Duplicate LFB Laboratory Fortified Blank <br />CCB Continuing Calibration Blank LFM Laboratory Fortified Matrix <br />CCV Continuing Calivation Verification standard LFMD Laboratory Fortified Matrix Duplicate <br />DUP Sample Duplicate LRB Laboratory Reagent Blank <br />ICB Initial Calibration Blank MS Matrix Spike <br />ICV Initial Calibration Verification standard MSD Matrix Spike Duplicate <br />ICSAB Inter-element Correction Standard - A plus 6 solutions PBS Prep Blank - Soil <br />LCSS Laboratory Control Sample - Soil PBW Prep Blank - Water <br />LCSSD Laboratory Control Sample - Soil Duplicate PQV Practical Quantitation Verification standard <br />LCSW Laboratory Control Sample - Water SDL Serial Dilution <br /> method or calibration <br />rocedure <br />in <br />ti <br />n in the <br />re <br />i <br />l <br />if <br />h <br />t th <br />i <br />i <br />t <br />V <br />Blanks n <br />ma <br />con <br />am <br />o <br />ies t <br />ere <br />s no or m <br />a <br />er <br />a p <br />. <br />p <br />p <br />Control Samples Verifies the accuracy of the method, including the prep procedure. <br />Duplicates Verifies the precision of the instrument and/or method: <br />Spikes/Fort ified Matrix Determines sample matrix interferences, if any. <br />Standard Verifies the validity of the calibration. <br />111137-TIFIRI <br />• . <br />B Analyle concentration detected at a value between MDL and PQL. <br />H Analysis exceeded method hold time. pH is a field test with an immediate hold time. <br />U Analyte was analyzed for but not detected at the indicated MDL <br />(1) EPA 600/4-83-020. Methods for Chemical Analysis of Water and Wastes, March 1983. <br />(2) EPA 600/R-93-100. Methods for the Determination of Inorganic Substances in Environmental Samples, August 1993. <br />(3) EPA 600/R-94-111. Methods for the Determination of Metals in Environmental Samples - Supplement I, May 1994. <br />(5) EPA SW-846. Test Methods for Evaluating Solid Waste, Third Edition with Update III, December 1996. <br />(6) Standard Methods for the Examination of Water and Wastewater, 19th edition, 1995. <br />(1) QC results calculated from raw data. Results may vary slightly if the rounded values are used in the calculations. <br />(2) Soil, Sludge, and Plant matrices for Inorganic analyses are reported on a dry weight basis. <br />(3) Animal matrices for Inorganic analyses are reported on an "as received" basis. <br />REPIN03.02.07.01 <br />Page 5 of l l