Laserfiche WebLink
• • • <br /> TABLE 1. Pred icted Longwa <br />ubsidence Maxima for Virgin <br /> Ground at Selected Overburden Depths <br />Mining Single Longwell Panel Multiple Longwell Panels <br />Depth Vertical Tensile Compressive Tilt Vertical Tensile Compressive Tilt <br />(f t) (Smyx ft) Strain Strain (G min) (S~x ft) Strain Strain (G min) <br /> (+E Nf ) (-E yf) (+E .uE) (-E 4E) <br /> <br />1200 3.82 2500 4090 36.0 6.48 3510 2750 51.0 <br />1500 2.74 1400 2900 20,9 6.48 2810 2200 40.8 <br />1600 2.45 1150 2560 16.6 6.48 2630 2070 38.3 <br />:~~• <br />2000 1.66 590 1600 8.5 6.48 2110 1650 30.0 <br />2400 1.40 340 1110 4.9 6.48 1760 1380 22,5 <br />