Laserfiche WebLink
GP-C2-Edited.OPT <br />The following is a summary of the TEN most critical surfaces <br />Problem Description : West Farm - Case C - 2:1 <br /> FOS Circle Center Radius <br /> (BISHOP) x-coord y-coord <br /> (ft) (ft) (ft) <br />1. 1.385 117.32 412.62 209.37 <br />2. 1.387 109.72 431.79 228.42 <br />3. 1.391 123.43 398.48 195.45 <br />4. 1.395 122.31 401.64 198.49 <br />5. 1.401 116.70 415.78 212.26 <br />6. 1.407 84.98 494.17 290.91 <br />7. 1.407 102.16 451.80 248.06 <br />8. 1.422 113.39 425.01 221.05 <br />9. 1.422 125.46 395.61 192.27 <br />10. 1.426 111.77 428.78 224.67 <br />Initial Terminal <br />x-coord x-coord <br />(ft) (ft) <br />62.25 270.55 <br />59.09 270.93 <br />64.96 270.67 <br />64.51 270.82 <br />62.25 270.92 <br />51.42 270.35 <br />56.84 270.90 <br />61.35 270.93 <br />66.32 271.00 <br />60.90 270.67 <br />Resisting <br />Moment <br />(ft-lb) <br />8.023E+07 <br />8.713E+07 <br />7.527E+07 <br />7.655E+07 <br />8.176E+07 <br />1.091E+08 <br />9.445E+07 <br />8.553E+07 <br />7.472E+07 <br />8.683E+07 <br />* * * END OF FILE * * * <br />Page 5