Laserfiche WebLink
SEDCAD 4 for Windows <br />11 <br />Design Discharge = 26.43 cfs <br />Minimum pipe diameter: 1 - 30 inch pipe(s) required <br />Structure #4 LErodib/e Channel) <br />DRPE-1 <br />Triangular Erodible Channel Inputs: <br />Material: Cobbles and shingles <br />Left Right Freeboard Freeboard Freeboard Limiting <br />Sideslope Sideslope Slope (%) Manning's n Depth (ft) % of Mult. x <br />Depth Velocity <br />(fps) <br />Ratio Ratio (VxD) <br />2.0:1 2.0:1 9.0 0.0350 0.30 5.5 <br />i <br />Erodible Channel Results: <br /> w/o Freeboard w/ Freeboard <br />Design Discharge: 2.92 cfs <br />Depth: 0.54 ft 0.84 ft <br />Top Width: 2.17 ft 3.37 ft <br />Velocity: 4.97 fps <br />X-Section Area: 0.59 sq ft <br />Hydraulic Radius: 0.242 ft <br />Froude Number: 1.68 <br />Structure #3 (Culvert) <br />CRPE-1 <br />Culvert Inputs: <br />Tailwater Entrance <br />Length (ft) Slope (%) Manning's n He Max. adwater (ft) Loss Coef. <br />(ft) (Ke) <br />20.00 5.00 0.0240 1.50 0.00 0.9( <br />Culvert Results: <br /> <br />Design Discharge = 2.92 cfs <br />Minimum pipe diameter: 1 - 12 inch pipe(s) required <br />Structure #2 Ll onerodible Channel) <br />DRPE-2 <br />Triangular Nonerodible Channel Inputs: <br />Material: Shotcrete <br />Filename: RPE(expanded).sc4 Printed 10-23-2008