Laserfiche WebLink
SEDCAD 4 for Windows <br />91 <br />Structure #13 (Nonerodible Channel) <br />• DCW--2 <br />Triangular Nonerodible Channel Inputs: <br />Material: Shotcrete <br />Left Right Freeboard Freeboard Freeboard <br />Sideslope Sideslope Slope (%) Manning's n Mult. x <br />Ratio Ratio Depth (ft) % of Depth (VxD) <br />2.0:1 2.0:1 4.0 0.0170 0.30 <br />Nonerodible Channel Results: <br /> w/o Freeboard w/ Freeboard <br />Design Discharge: 3.96 cfs <br />Depth: 0.54 ft 0.84 ft <br />Top Width: 2.16 ft 3.36 ft <br />Velocity: 6.79 fps <br />X-Section Area: 0.58 sq ft <br />Hydraulic Radius: 0.241 ft <br />Froude Number: 2.31 <br />• Structure #10 LErodib/e Channel) <br />D2R-7 <br />Triangular Erodible Channel Inputs: <br />Material: Graded silts to cobbles when colloidal <br />Left Right Freeboard Freeboard Freeboard Limiting <br />Sideslope Sideslope Slope (%) Manning's n Mult. x Velocity <br />Ratio Ratio Depth (ft) % of <br />Depth (VxD) (fps) <br />2.0:1 2.0:1 12.0 0.0300 0.30 5.5 <br />Erodible Channel Results: <br /> w/o Freeboard w/ Freeboard <br />Design Discharge: 1.02 cfs <br />Depth: 0.33 ft 0.63 ft <br />Top Width: 1.31 ft 2.51 ft <br />Velocity: 4.77 fps <br />X-Section Area: 0.21 sq ft <br />Hydraulic Radius: 0.146 ft <br />Froude Number: 2.08 <br />0 Structure 13F9 (Culvert) <br />Filename: MB-2R.sc4 Printed 10-23-2008