Laserfiche WebLink
SEDCAD 4 for Windows <br />70 <br />C2-11A <br />Culvert Inputs: <br />Culvert Results: <br />Max. Tailwater Entrance <br />Length (ft) Slope (%) Manning's n Headwater ft Loss Coef. <br />(ft) () (Ke) <br />104.00 5.00 0.0240 2.25 0.00 0.90 <br />Design Discharge = 1.27 cfs <br />Minimum pipe diameter: 1 - 8 inch pipe(s) required <br />Structure #62 (Cu/vert) <br />C2-11 <br />Culvert Inputs: <br />Max. Tailwater Entrance <br />Length (ft) Slope (%) Manning's n Headwater (ft) Loss Coef. <br />(ft) (Ke) <br />81.00 5.00 0.0240 6.00 0.00 0.90 <br />Culvert Results: <br />Design Discharge = 22.05 cfs <br />Minimum pipe diameter: 1 - 21 inch pipe(s) required <br />Structure #61 (Nonerodib/e Channel) <br />D2-4A <br />Triangular Nonerodible Channel Inputs: <br />Material: Shotcrete <br />Left Right Freeboard Freeboard Freeboard <br />Sideslope Sideslope Slope (%) Manning's n Mult. x <br />Ratio Ratio Depth (ft) % of Depth (VxD) <br />2.0:1 2.0:1 17.0 0.0170 0.30 <br />Nonerodible Channel Results: <br /> <br /> w/o Freeboard w/ Freeboard <br />Design Discharge: 0.74 cfs <br />Depth: 0.22 ft 0.52 ft <br />Top Width: 0.88 ft 2.08 ft <br />Velocity: 7.70 fps <br />X-Section Area: 0.10 sq ft <br />Hydraulic Radius: 0.098 ft <br />Froude Number: 4.09 <br />Filename: MB-2R.sc4 Printed 10-23-2008