Laserfiche WebLink
TRIAXIAL COMPRESSION TEST DATA <br />ASTM D 4767 <br />• <br />CLIENT <br />GEI Consultants <br />JOB NO. <br />2076-137 <br />BORING NO. <br />DEPTH <br />SAMPLE NO. <br />SOIL DESCR. <br />LOCATION: <br />TEST TYPE <br />MOISTURE/DENSITY <br />DATA <br />Wt. Soil + Moisture (g) <br />Wt. Wet Soil & Pan (g) <br />Wt. Dry Soil & Pan (g) <br />Wt. Lost Moisture (g) <br />Wt. of Pan Only (g) <br />Wt. of Dry Soil (g) <br />Moisture Content % <br />Wet Density PCF <br />Dry Density PCF <br />Init. Diameter (in) <br />}} Init. Area (sq in) <br />l Init. Height (in) <br />Vol. Bef. Consol. (cu ft) <br />Vol. After Consol. (cu ft) <br />Notes & Comments: <br />BL-102 <br />19.2-19.5' <br />U-1, Pt. B <br />Project #99292 <br />Bruce Park Dam <br />TX/CUpp <br />BEFORE AFTER <br />TEST TEST <br />360.5 363.5 <br />368.8 371.8 <br />308.3 308.3 <br />60.5 63.5 <br />8.3 8.3 <br />300.0 300.0 <br />20.2 21.2 <br />125.9 127.6 <br />104.8 105.3 <br />1.860 <br />2.717 <br />4.014 <br />0.00631 <br />0.00628 <br />Data entry by: SR Date: 01/10/2002 <br />Data checked by: Y-P- Date: 1 to Zmv <br />FileName: GIT02U1B <br />SAMPLED <br />TEST STARTED <br />TEST FINISHED <br />CELL NUMBER <br />SATURATED TEST <br />CONF. PRES. PSF <br />12-31-01 CAL <br />1-8-02 CAL <br />18S <br />Yes <br />1440 <br />ADVANCED TERRA TESTING, INC.