My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-11-24_PERMIT FILE - C1996083 (13)
DRMS
>
Day Forward
>
Permit File
>
Coal
>
C1996083
>
2008-11-24_PERMIT FILE - C1996083 (13)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:38:13 PM
Creation date
2/23/2009 5:37:04 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1996083
IBM Index Class Name
Permit File
Doc Date
11/24/2008
Doc Name
Addendum to Geotechnical Data Report Bruce Park Dam, GEI Consultants, July 2002
Section_Exhibit Name
Volume X Bruce Park Dam Geotechnical Studies
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Addendum to Geotechnical Data Report <br />Bowie Resources, Limited <br />July 2002 <br />u-clamps are attached to the galvanized steel cable every 1 to 2 feet. The purpose of the <br />u-clamps is to improve the bond with the Portland cement. The coaxial cable is attached to <br />the steel cable about 5 feet below the estimated failure surface with black electrical tape. The <br />coaxial cable extends about 5 feet above ground. The PVC sheath extends 2 to 3 feet above <br />ground and the galvanized steel cable extends about 25 to 30 feet above ground. Details for <br />an inclinometer are shown on Figure 4. <br />Where a piezometer was installed in the same boring as an inclinometer, then the procedure <br />for installing a piezometer as described in Section 2.3 was followed and the backfill <br />procedure for the inclinometer previously provided was modified accordingly. Details for a <br />combined piezometer/inclinometer are shown on Figure 5. A summary of the inclinometer <br />installations is presented in Table 2.3 and the influence zones are shown in section on Figure <br />6. Logs of inclinometer installations are provided in Appendix A. <br />TABLE 2.3 <br />INCLINOMETER INSTALLATION INFORMATION <br />10) <br /> <br /> Approximate Instal lation Depths (feet) <br /> Elevation at Depth to Bottom of Bottom of Bottom <br />Boring Ground Bottom of Steel Coaxial of PVC <br />Number Surface Boring Cable Cable Sheath <br /> (feet) <br />BL-101A 8230 29.5 29.0 22.0 18.0 <br />BL-102A 8209 29.5 29.0 24.0 19.0 <br />GEI Consultants, Inc. <br />99292 02-07-03 Addendum Geotechnical Data Rpt
The URL can be used to link to this page
Your browser does not support the video tag.