Laserfiche WebLink
043--- - <br />Work Order: 08-8652 <br />Client Project ID: <br />ANALYTICAL QC SUMMARY REPORT <br />TestCode: TDS W <br />Sample ID MBLK 111208 SampType: MBLK TestCode: TDS_W Run ID: ANALYTICAL BALANCE 081112A Prep Date: 11112/2008 Units: mg/l. <br /> Batch ID: R43433 TestNo: SM 2540C FilelD: 47 Analysis Date: 11/12/2008 SegNo: 768582 <br />Analyte Result LQL SPK value SPK Ref Val %REC Lowl-imit HighLimit RPD Ref Val %RPD RPDLimit Qual <br />Total Dissolved Solids U 10.0 <br />Sample ID LCS SampType: LCS TestCode: TDS_W Run ID: ANALYTICAL BALANCE-081112A Prep Date: 1111212008 Units: mg/L <br /> Batch ID: R43433 TestNo: SM 2540C FilelD: 48 Analysis Date: 11/12/2008 SegNo: 768583 <br />Analyte Result LQL SPK value SPK Ref Val %REC Lowl-imit HighLimit RPD Ref Val %RPD RPDLimit Qual <br />Total Dissolved Solids <br />403 10.0 400 0 101 . 90 110 <br />0 0 <br />Qualifiers: U - Not detected at or above the Reporting Limit R - RPD outside acceptance limits <br />- Analyte detected below quantitation limits B - Analyte detected in the associated Method Blank <br />S - Spike Recovery outside acceptance limits H - Prep or analytical holding time exceeded <br />E - Extrapolated value, value exceeds calibration range. X - See case narrative