Laserfiche WebLink
Model calibration DRAFT 21 <br />The resulting calibration is shown in Figures 4.4 through 4.6. These figures illustrate: <br />• the hydraulic response in the F/G sequence (Figure 4.4); <br />• the hydraulic response in the bedrock units directly above the F/G <br />sequence (Figure 4.5); and <br />• the hydraulic response in the bedrock units directly below the F/G <br />sequence (Figure 4.6). <br />The hydraulic parameters from the transient calibration were feed back into the regional <br />model to refine the final steady-state calibration. <br />The internal mass balance of the transient model was also evaluated. The difference <br />between fluxes into and out of the model was about 0.2%, indicating excellent internal <br />consistency. <br /> <br /> <br />2572-R3 Colowyo Coal Company, L.P. <br />Water Management Consultants