My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-01-02_INSPECTION - M1977344
DRMS
>
Day Forward
>
Inspection
>
Minerals
>
M1977344
>
2009-01-02_INSPECTION - M1977344
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:39:23 PM
Creation date
1/6/2009 3:19:44 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977344
IBM Index Class Name
INSPECTION
Doc Date
1/2/2009
Doc Name
Detailed Facilities Inventory
From
Holcim
To
DRMS
Inspection Date
12/19/2007
Email Name
BMK
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Facilities Map Key - Holcim (US) Inc. <br />Portland Plant <br />3500 State Highway 120 <br />Florence CO. 81226 <br />Building Number Area Descri <br />tio <br /> p <br />n Year Built Square Ft Materials of Construction <br />Foundation <br />1 Plant 3 Plant Warehouse & Maintenance 1970 16,000 Metal Siding Bldg Caisson 16ea at 2'-6" dia. X 10' 14ea at 4' dia. X 10' A <br />7' tall x 10" width stem wall that sits on the caissons <br /> . <br />2 Plant 3 Service Building 1970 4,160 Concrete Twin Tee Wall 2'-6"x 2' Footer along perimeter of bldg. A stem wall 7" wide <br />x 1'-6" tall with a 6" floor mat <br /> <br />3 Plant 3 1974 Mill Complex, Air Se <br />Perator <br />1974 <br />4,445 <br />Concrete Twin Tee Wall Caisson 45 ea at 2'-6" dia. X 20', 3ea at 4' dia. X 10', 63 ea <br />at 3' dia. X 16'. With a 10" wide x 2'-6" tall stem wall on top <br />o <br /> f caissons on outside perimeter. <br />4 Plant 3 1974 Mill Complex, Finish Mill Area 1974 9,779 Concrete Twin Tee Wall The one above this covers this section of bldg. <br /> <br />5 Plant 3 1974 Mill Complex, Old Compressor Room & Control Room 1974 10,744 Concrete Twin Tee Wall Caissons Type A's 10 ea at 7-6" dia x 20' Type E's 7 ea at 3' <br />dia x 20' <br /> <br />6 Plant 3 1974 Mill Complex, Cooler, New Office Area Added 1974 22,179 Concrete Twin Tee Wall Caissons Type A's 25 ea 7-6" dia x 20' Type B's 13 ea at 3' <br />dia. X 20' <br /> <br />7 Plant 3 Control Room & Pump House <br />1974 <br />4,560 <br />Concrete Twin Tee Wall Tank 1' thick x 8' tall stem wall all around perimeter of tank. <br />Pumphouse 4' wide x 1' tall footer with 1'-7" thick wall by 4'- <br />" <br /> 6 <br />tall stem wall. <br />8 Quarry So. Quarry Garage 1954 5,457 Concrete Twin Tee Wall Caissons 14 ea at 7-6" dia x 2', has a 2'-6" x 3' footer along <br />perimeter with an 8" concrete floor <br /> <br />9 Quarry No. Quarry Garage 1974 5,664 Concrete Twin Tee Wall Could not find any drawings but assume as the one above <br /> <br />9A Quarry Lubrication Oil Shed 1974 800 Concrete Wall Footer V x 2'x 2' with a 10" x 3' stem wall with 8" x 8" <br />runners connecting the footer <br /> <br />9B Quarry Fuel Shelter 1997 1,232 Concrete Pillars Concrete pad 9" thick <br /> <br />9C Quarry Truck Wash 2004 300 Metal siding bldg Stem Wall 3'-6" x 9" thick with a 2' wide x 9" thick footer <br /> <br />10 Quarry Quarry Area Electric Substation 1974 672 Concrete Twin Tee Wall Concrete slab 6" thick <br /> <br />11 Misc. Service Building & Warehouse 1994 15,312 Concrete Wall Spread Footer every 22'8'x 4'-6" 33 total with a 2'-6" x 10" <br />stem wall <br /> <br />12 Misc. Utility Storage Building 1994 3,830 Building does not exist <br /> <br />13 Misc. A dministration Office 1994 5,856 Center Block Wall 1 <br />a 0" tall x 16" wide footer with a 8" wide x 26" tall stem wall <br />long perimeter of bldg with a 6" concrete pad.