Laserfiche WebLink
RULE 4 PERFORMANCE STANDARDS <br />4.27 Operations on Steep Slopes <br />Colowyo will conduct no surface coal mining or reclamation on "steep slopes" as defined by grades in <br />excess of 20 degrees by Rule 4.27; therefore, this part is not generally applicable to this permit <br />application. <br />As discussed in Section 4.14.2, final grading will be accomplished such that overall grades will not <br />exceed lv:3h. Rule 4.27 requires that a showing be made which demonstrates a minimum static factor of <br />safety of 1.3 for all portions of the reclaimed land. <br />The following analysis is provided for that demonstration: <br />As a general observation, such a demonstration can easily by made when postmining grades do not <br />exceed lv:3h (approximately equivalent to 18.4 degrees). For example, assuming a cohesionless dumped <br />spoil slope with a 3H:1 V slope composed of 125 lbs/sq. ft. in-place density and an internal friction angle <br />(phi) of 35 degrees, the safety factor F for this "infinite slope" problem simplifies to: <br />F = tan (35 degrees) /tan(18.4 degrees) = 2.1 <br />This factor is well above the required safety factor of 1.3. This analysis assumes that no phreatic surface <br />has developed, i.e. no groundwater is present. For the purposes of this analysis, this is a valid <br />assumption. According to the U.S. Army Corp. of Engineers Manual entitled "Engineering Design, Slope <br />Stability, October, 2003" (EM 1110-2-1902), in the case of cohesionless soils, "the critical mechanism is <br />shallow sliding, which can be analyzed as the infinite slope failure mechanism." In this case, a graphical <br />solution from the manual can be used to verify the equation above. <br />The calculated factor of safety shown above is for a shallow surface failure, and that surface is <br />controlling. A deeper-seated, larger failure surface would have an even higher factor of safety. It is also <br />generally recognized that such a 2-dimensional analysis is conservative. This is because it does not <br />account for additional soil strength that occurs when 3-dimensional effects are considered. <br />In addition, each of the spoil pile designs (Streeter Fill, West Pit Fill, and Section 16 Fill) contain further <br />information regarding other stability analyses that have been performed. These include additional <br />information regarding material properties, hydrologic assumptions, and laboratory testing results that <br />have been performed as components of the stability analyses. See Section 2.05.3 and Exhibit 19 for more <br />information. <br />Rule 4 Performance Standards 4.27-1 Revision Date: 6/23/08 <br />Revision No.: MR-91