Laserfiche WebLink
:M <br />.~ <br />;~: <br />` HYDROLOGIC DOCUMENTATION <br />• SMALL AREA EXEMPTION <br />D-SEAM SOIL STOCKPILE - TOP OF PILE <br />The following calculations demonstrate the amount of silt fence or straw bales <br />surface area required to adequately handle the runoff from the Top of the soil <br />stockpile located at the D-Seam portal. <br />Runoff volume and peak discharge calculations were performed utilizing the <br />SEDCAD 4 computer model consistent with the methodology previously discussed in <br />this Exhibit. The sediment control structure was designed to handle the peak <br />discharge from a 10-year, 24-hour storm event. <br />1 Hydrology Inputs <br />All hydrology inputs are shown on the SEDCAD 4 computer printouts. <br />The CN numbers used for the SAE watershed were obtained from Procedures <br />for Determining Peak Flows in Colorado and Technical Release No. 55 <br />(USDA-SCS, 1980)and consistent with previously approved hydrology <br />reports. Based on soil type and vegetation cover, curve numbers were <br />determined using Table 2-2a and 2-2 d, USDA-SCS TR-55, for the following <br />conditions: <br /> Reclaimed (< 2 years) <br /> Soil Type: C <br /> Ground Cover: <50~, Interim Vegetation <br /> Cover Type: Herbaceous <br /> CN: 87 <br />Area: 0.46 ac <br /> 2 Hydrology Results <br /> Peak Discharge In <br /> 10-year,24-hour event 0.45 cfs <br /> Peak Discharge Out - Silt Fence <br /> 10-year,24-hour event 0.43 cfs <br /> Peak Discharge Out - Straw Bales <br /> 10-year,24-hour event 0.44 cfs <br />3. Sediment Fence Requirements <br />- - - -- -- -- -- - - - -- --- - - - -- ---- _ _ _ -- - ... 1 <br />Sediment Fence Permissivity: 10 gal/min/ft2 or 0.022 cfs/f t2 <br />Required Surface Area: 0.43 cfs / 0.022 cfs/ftz = 19.5 ftz <br />The silt fence should be installed in accordance with the manufactures <br />recommendations. Design assumes regular inspections and maintenance. <br />4. Straw Bale Requirements <br />Straw bale Permissivity: 14 gal/min/ftz or 0.031 cfs/f t2 <br />Required Surface Area: 0.44 cfs / 0.031 cfs/ftZ = 14 ftZ <br />M~ ~~~ <br />