Laserfiche WebLink
Elk Creek Mine TR-60 <br />Adequacy Review <br />10 Nov 2008 <br />Page 2 of 5 <br />designated as an SAE on Map 2.05-El-BCA2, nor are there any Sedcad designs <br />for them. Please revise Map 2.05-E1-BCA2 to indicate that the entire disturbed <br />area is designated as an SAE and provide appropriate Sedcad designs for the <br />remaining disturbed areas. <br />4. Please explain why there is no small area exemption area at the south or outlet <br />end of the Bear Creek fan site culvert, as was done at the north or inlet end of the <br />culvert. <br />5. There are no hydrology and sedimentology Sedcad designs for the proposed <br />check dams in drainage channel BCCD-1 to show that the check dams can handle <br />the flow and meet the settable solids limit of 0.5 ml/1. Please provide these Sedcad <br />designs. <br />6. There are no Sedcad designs for the check dams that show the construction <br />requirements for the check dams. Since the check dams are part of a designed <br />sediment control structure, please revise the Sedcad designs to show their <br />construction requirements. <br />7. The Sedcad designs for the small area exemptions at the north area, topsoil <br />storage area and the lay down area do not include sediment analyses to show that <br />the 0.5 ml/1 settable solids limit can be achieved. Please revise the Sedcad designs <br />accordingly. <br />8. None of the Sedcad designs for the small area exemptions that use silt fence or <br />straw bales for sediment control shows the construction requirements, such as <br />length, height and tie back distance. Only the required surface area is given. Since <br />the silt fence and straw bales are part of a designed structure, please revise the <br />Sedcad designs to show the construction requirements for the silt fence and straw <br />bales. <br />9. Please add a notation in the legend for Map 2.05-E1-BCA2 that explains the use <br />of yellow color to designate small area exemption areas. <br />10. No entry road is designated on Map 2.05-E1-BCA2. Please explain how the fan <br />site will be accessed from the Bear Creek ranch road and whether or not a road <br />culvert will be needed. <br />11. Map 2.05-E1-BCA2 does not show how the lay down area will be accessed. <br />Please explain if a road will be needed and whether this road will require a road <br />culvert in the small drainage just north of the lay down area. <br />12. In comparing the existing topography shown on Map 2.05-E1-BCAl with the <br />proposed post mining topography shown on Map 2.05-M6, it appears that there is