Laserfiche WebLink
Mr. Roy Karo <br />October 27, 2008 <br />Page 2 <br />followed for all Stock Ponds that are to be retained as permanent structures. <br />Please provide the DRMS with documentation that proper notification has <br />occurred and all pertinent requirements have been met, and revise the Permanent <br />Stock Pond Evaluation in Appendix 13-9 of the PAP accordingly to reflect this. <br />3. The revised text for Appendix 13-9, states that water sampling during the bond <br />release period will be used to confirm the assumption that there are no anticipated <br />problems with regard to water quality at all of the stock ponds. Since SCC is well <br />into the bond release period this would be an appropriate time to confirm water <br />quality at all of the stock ponds that are to be retained as permanent. Please <br />provide the DRMS with a specific commitment to conduct water sampling and <br />analysis to demonstrate compliance with 4.05.9(13) (a). <br />4. The table listing on page 1 of the amended Appendix 13-9 text, which lists "Stock <br />Ponds to be Retained as Permanent Structures", appears to have a couple errors. <br />The listing erroneously includes Stock Pond T-9 (not listed elsewhere in text, <br />tables, and maps), and does not list Stock Ponds T-8 and T-16 (which are listed in <br />the various other text sections, tables and maps). Please correct the table and <br />provide a revised page 1 of Appendix 13-9. <br />If you have questions or need additional information, please contact me. <br />Sincerely, <br />A-44 I3 <br />?L- <br />Daniel T. Mathews <br />Environmental Protection Specialist <br />C: Denver File