SOP No. 22.0 Purging and Sampling Monitoring Well <br />the bottom of the bailer. At the pump discharge end, attach a clean 0.45-micron <br />filter to the Teflon tubing. <br />Turn on the pump and draw the water through the bailer, through the pump and <br />filter, and into the sample container. <br />4. Disassemble the pump head and discard the polyethylene and Teflon tubing and <br />filter in a plastic bag. <br />6.0 QUALITY ASSURANCE/QUALITY CONTROL <br />All activities conducted under this SOP are subject to quality assurance and quality <br />control audits. Corrective action will be implemented immediately. <br />7.0 DOCUMENTATION <br />All actions will be documented in accordance with SOP 52 "Note Taking and Log Book <br />Entries. <br />8.0 REFERENCES <br />EPA, March 2001, Guidance for Preparing Standard Operating Procedures <br />(SOPs) EPA QA/G-6, EPA/240/B-02/004, Office of Environmental Information, <br />Washington, D.C. <br />EPA, March 2001, EPA Requirements for Quality Management Plans, EPA A/R- <br />2, EPA/240/B-02/002, Office of Environmental Information, Washington, D.C. <br />EPA, November, 2002, Guidance on Environmental Verification and Data <br />Validation, EPA QA/G-8, EPA/240/R-02/004, Office of Environmental Information, <br />Washington, D.C. <br />EPA, December 2002, Guidance for Quality Assurance Project Plans, EPA AQ/G-5, <br />EPA/240/R-2/009, Office of Environmental Information, Washington, D.C. <br />7/17/07 Page 6 of 9 R Squared Inc.