Laserfiche WebLink
ENEROYLABORATOR/ES, INC. • 2393 Sa/1 Creek Highway (82601) • P.O. Box 3258 • Casper, WY82602 <br />To//Free 888 235 0515 - 307.235.0515 - Fax 307.234.1639 • casperiVenergy/ab.com • www.energy/ab.com <br />LABORATORY ANALYTICAL REPORT <br />Client: Cotter Corporation <br />Project: Schwartzwalder <br />Lab ID: C08050250-013 <br />Client Sample ID: WTP # 2 Report Date: 06/15/08 <br />Collection Date: 04/16/08 <br />DateReceived: 05/02/08 <br />Matrix: Concrete <br /> MCLI <br />Analyses Result Units Qualifiers RL QCL Method Analysis Date / By <br />PHYSICAL PROPERTIES <br />Filterable No SW1311 05/08/08 08:33 / dcj <br />METALS-TCLP <br />Uranium ND mg/L 1 SW6010B 05/29/08 20:12 / cp <br />RADIONUCLIDES - TCLP <br />Radium 226 -0.5 pCi/L U E903.0 05/21/08 12:03 / taj <br />Radium 226 precision (t) 0.7 pCVL E903.0 05/21/08 12:03 / taj <br />Radium 226 MDC 1.3 pCVL E903.0 05/21/08 12:03 / taj <br />Thorium 230 0.1 pCVL U 0.2 E907.0 05/13/08 16:00 / dmf <br />Thorium 230 precision (t) 0.2 pCi/L E907.0 05/13/08 16:00 / dmf <br />Report RL - Analyte reporting limit. MCL - Maximum contaminant level. <br />Definitions: QCL - Quality control limit. ND - Not detected at the reporting limit. <br />MDC - Minimum detectable concentration U - Not detected at minimum detectable concentration