Laserfiche WebLink
<br />TABLE 3 <br />INTERFACE DIRECT SHEAR TEST RESULTS <br />MEASURED PEAK AND RESIDUAL TOTAL SHEAR STRENGTHS <br />GOLDER ASSOCIATES, INC. <br />GOLDER PROJECT NUMBER 933-2442.9 <br />Test Normal (11 Measured Peak Measured Residual Reference <br />Series Stress Shear Strength Shear Strength Appendix <br />Number (psi) (psi) (psi) Figure Number <br />1 50 35.5 35.5 1-1 and 1-2 <br /> 100 68.5 68.5 <br /> 150 88.9 88.9 <br /> 300 170.0 170.0 <br />Note: m For the 50. 100. and 150 psi tests. a 12-in. by 12-in. (300-mm by 300-ma) shear box was used <br />and the 300 psi test was conducted in a 6-1n. 2y 6-in. (ISO-= by ISO-=) shear box. Each test <br />specimen was sheared immediately after application of the normal stress. <br />)GL3458/GEL93234 93.09.29