Laserfiche WebLink
<br />Worksheet <br />Worksheet for Pressure Pipe <br />(,tl~ST- SSA <br />-_ <br />Project Description <br />Worksheet Pressure Pipe - 1 <br />Flow Element Pressure Pipe <br />Method Hazen-Williams Fo <br />Solve For Pressure at 1 <br />Input Data <br />Pressure at : 0.00 feet H2t <br />Elevation at ,849.00 ft <br />Elevation at ,849.00 ft <br />Lengih 400.00 ft <br />C Coefficien 150.0 <br />Diameter 4.0 in <br />Discharge 0.10 cfs <br />Results <br />Pressure at 1 0.52 feet H2i <br />Headloss 0.52 ft <br />Energy Grade at ,849.54 ft <br />Energy Grade at ,849.02 ft <br />Hydraulic Grade ; ,849.52 ft <br />Hydraulic Grade ; ,849.00 ft <br />Flow Area 0.1 ft' <br />Wetted Perimeter 1.05 ft <br />Velocity 1.15 ft/s <br />Velocity Head 0.02 ft <br />Friction Slope 001308 ft/ft <br />Project Engineer: Brad Hagen <br />c:\program files\haestad\fmva\proJectl.fm2 Civil Resources, LLC FlowMaster v7.0 [7.0005) <br />03/09/07 02:02:46 PM ®Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA +1-203-755-1686 Page 1 of 1 <br />