My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-03-10_GENERAL DOCUMENTS - M1977247
DRMS
>
Day Forward
>
General Documents
>
Minerals
>
M1977247
>
2008-03-10_GENERAL DOCUMENTS - M1977247
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:24:39 PM
Creation date
6/5/2008 8:35:56 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977247
IBM Index Class Name
GENERAL DOCUMENTS
Doc Date
3/10/2008
Doc Name
Scope of work for preblast surveys & water well analysis
From
Holcim
To
DRMS
Email Name
ACS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. August 10, 2007 <br />Quality Assurance Plan Version 12 ' <br />SOPAD018.08.07.12 Page 30 of 96 <br />8 PROCUREMENT, INVENTORY & TRACEABILITY OF SUPPLIES <br />8.1 Procurement / Inventory <br />All consumable supplies are purchased from reputable vendors that have been evaluated for service, quality, , <br />and price. To the extent possible, materials traceable to national or international standards of measurement are <br />purchased for use in technical operations. Supplies are purchased using ACZ's purchase order (PO) and <br />inventory system database. The Purchasing Agent is not permitted to make a substitution for any material(s) <br />specifically requested unless the department supervisor approves the substitution. Upon receipt, reagents, _ <br />chemicals, standards, and other laboratory consumables are stored in the Chemical & Supply Room, which has <br />limited access, or are delivered to the laboratory. Refer to ACZ's SOP Purchase, Receipt, and Storage of <br />Consumable Materials for Technical Operations (SOPAD037) for additional information. <br />8.2 Glassware <br />ACZ uses only laboratory grade glassware. Prior to use, glassware is cleaned using Alconoxo or Chemsolveo (or i <br />other appropriate detergent) and then rinsed with Type I water. Glassware for trace metals is subsequently rinsed <br />with 50% Nitric Acid and rinse again with Type I water. Glassware for nutrients is subsequently rinsed with 10% , <br />Hydrochloric Acid and then with Type I water. All glassware for organic analyses is washed with Alconoxo then <br />rinsed with de-ionized water and kiln-baked. Glassware for radiochemistry analyses is washed first with <br />Contrad700 and then with 50% Nitric Acid and is rinsed with Type I water. Clean glassware must be stored in an , <br />enclosed cabinet or other suitable container and/or covered with Parafilm or foil. <br />8.3 Other Supplies <br />Routine consumables (centrifuge tubes, autosampler tubes, pipette tips, etc.) are purchased through an automatic , <br />system managed by Fisher (RIMS). All other supplies are purchased on an as-needed basis through ACZ's <br />Purchase Order and inventory system database. Refer to SOPAD037 for additional information. <br />8.4 Traceability of Standards and Reagents <br />To provide complete traceability, each data package must reference every standard and reagent used for sample <br /> <br />preparation or analysis, including but not limited to acids, bases, preservatives, color reagents, pH indicators, ' <br />buffers, instrument reagents. Each PCN and/or SCN must be documented either on the workgroup bench sheet, <br />data review checklist, or a current standard/reagent form. The open date for all original containers is not tracked in <br />s be noted on the sample container <br />en date alwa <br />ractice dictates that the o <br />however <br />ood laborator <br />LIMS <br />. <br />y <br />p <br />, g <br />y p <br />; <br />8.4.1 Primary Control Number (PCN) <br />Upon receipt, all stock chemicals, standards, and reagents are assigned a unique PCN in LIMS for <br />tracking and traceability purposes. A label with the PCN and the expiration date is affixed to both the <br />container and the Certificate of Analysis (if applicable). Document Control enters the data for each <br />PCN using the certified value(s) supplied by the vendor, as indicated on the Certificate of Analysis. <br />Because the certified value is entered, the final concentrations for prepared standards may vary <br />slightly from the theoretical value indicated in the test SOP. Non-certified values are not entered and <br />are not used for quality control purposes. Document Control maintains certificates of Analysis, and a , <br />copy of the PCN report is generated and maintained. If data for any PCN is to be edited, then <br />complete documentation must be provided as a major corrective action (FRMQA001). <br />NOTE: Only Document Control and QA/QC personnel are authorized to enter or edit PCN data. <br />2773 Downhill Drive 970-879-6590 <br />Steamboat Springs, CO 80487 www.acz.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.