Laserfiche WebLink
PERIODIC INSPECTION FORM <br />Water, Sediment, or Slurry Impoundments <br />INSPECTOR'S NAME: Dennis Jones DATE: 1 v <br />NPDES I D Mn <br />CO-0000221 D.P. 015 <br />FACILITY CONFIGURATION: Cross-Valley Pond DATE LAST INSPECTION: 1b _3 _ <br />SITE NAME: Pond #015 LOCATION: NEV4 SE'/. Sec 23 T5N R88W <br />MINE NAME: Seneca II-W Mine (Seneca Coal Co) LOCATION: 8 mi. S of Hayden CO <br />MINE I.D. NO.: CMLRD Permit No. C-82-057 OWNER'S REP.: Greag Kitchen Gen Mar <br />Circle or write in anvronriate response <br />1. Foundation preparation (removal of vegetation, stumps, topsoil: Yes <br />2. Lift thickness: <br /> <br />3. <br />Compaction according to approved plan: 12 <br /> <br />4. <br />Burning (specify extent and location): Yes <br /> <br />5. <br />Angle of slope: 2.5:1 upstream, 3.5:1 downstream No <br />Total = <br />6:1 <br />6. *Seepage (specify location, color, and approximate volume) <br /> From underdrain pipes: N/A <br /> At isolated points on embankment slopes: Yes N/A <br /> At natural hillside: <br /> <br />Over widespread areas: Yes r N/A <br /> <br />From downstream foundation area: Yes No NA <br /> <br />"Boils" beneath stream or ponded water: Yes <br />Yes N/A <br />N/A <br />7. Cracks or scarps on crest: Yes No N/A <br />8. Cracks or scarps on slope: Yes No N/A <br />9. Sloughing or bulging on slope: <br /> <br />10. <br />*Major erosion problems: Yes No N/A <br /> <br />11. <br />Surface movements in valley bottom or on hillside: qa Yes No N/A <br /> <br />12. c <br />*Erosion of toe: Ye No N/A <br /> <br />13. <br />*Water impounded against toe: Yes N N/A <br /> <br />14. <br />Exis ing embankment freeboard: (normal = 4.01) Yes No <br /> <br />feet N/A <br />15. Increase Decrease in water level: OJUS feet <br />16. Cracks, bulging, or erosion on upstream face: Yes (-Vo) N/A <br />17. Visible sumps or sinkholes in slurry surface: N/A <br />18. *Clogging <br /> Spillway channels and pipes: Yes No N/A <br /> Decant system: N/A <br /> Diversion ditches: <br /> <br />19. <br />*Cracking or crushing of pipes N/A <br /> Spillway pipes: Yes No N/A <br /> Decant system: N/A <br />20. Trash racks clear and in place: Yes No N/A <br />21. Discharge rate (gpm) ? G <br />*Major adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions noted in <br />these items should normally be described (extent, location, volume, etc.) in the space on the <br />back of this sheet. <br />c? "e," 0 % 6 L'L 3 L'?-) G ?-. v () L.,- (^ X?,- <br />? 3