2008-04-04_HYDROLOGY - C1981041 (5)
DRMS
>
Day Forward
>
Hydrology
>
Coal
>
C1981041
>
2008-04-04_HYDROLOGY - C1981041 (5)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:26:58 PM
Creation date
4/8/2008 1:10:27 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981041
IBM Index Class Name
Hydrology
Doc Date
4/4/2008
Doc Name
2008 Annual Impoundment Inspection
From
J.E. Stover & Associates, Inc
To
DRMS
Permit Index Doc Type
Prof Pond Certifications
Email Name
SB1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SNOWCAP COAL COMPANY <br />NORTH AND SOUTH PORTALS <br />IMPOUNDMENT YEARLY INSPECTION <br />In accordance with Rule 4.05.9(14), all impoundments shall be inspected at least yearly <br />to determine if the impoundment has been maintained as designed, and in accordance <br />with the approved plan and the applicable regulations. This yearly inspection is for the <br />impoundments located at the North and South Portals, Unit Train Loadout, North <br />Decline and Refuse Disposal Areas. <br />On March 18, 2008, I performed the required yearly inspections. I, J. E. Stover, have a <br />wide variety of experience in the design and construction of earth fill embankments. <br />Nothing was observed during the inspection that would indicate the ponds have a <br />potential for failure. There was no appearance of erosion, instability, structural <br />weakness or other hazardous conditions. There are no required monitoring procedures <br />or instrumentation other than quarterly and yearly inspections. Unless noted below in <br />the discussion of each pond, there are no aspects which might affect stability and there <br />is no required maintenance. None of the pond/impoundments were discharging during <br />the inspection. <br />Ponds 1 and 2 are located at the Unit Train Loadout. They were dry during the <br />inspection. Volume III, Appendix 13-2, page UTL-5 indicates the combined ponds are <br />designed to contain the 25-year 24 hour event and still have significant excess capacity. <br />The ponds were certified by Larry M. Reschke, P.E., on June 1, 1995. Based on the <br />certification statement and current measurements of the sediment poles, the sediment <br />capacity of the ponds has not been affected since .1995. Therefore, the sediment <br />ponds have significant excess capacity plus the following design capacity: <br /> Water Sediment Total <br />Ponds 1 & 2 - A-F 1.99 0.46 2.45 <br />Pond 6 collects run-off from CRDA-1. The pond was dry during the inspection. There <br />are approximately 2.3-feet of sediment buildup in the pond. This figure is derived from <br />the average length of the three sediment poles located in the pond minus the design <br />depth. The percent of sediment buildup is 43% (2.3' deep divided by 5:4' maximum <br />depth). Based on this sediment buildup and aerial topo maps, the pond has the <br />following estimated capacity: <br /> Water Sediment Total <br />Pond 6 - A-F 1.33 0.90 2.23 <br />-1- <br />