Laserfiche WebLink
ORIGINAL -PUBLIC FILE <br />(Page 2) <br />MINE ID # OR PROSPECTING ID #: M-IeRn-add <br />INSPECTION DATE: 3/~mR INSPECTORoS INITIALS: -B.I~- <br />OBSERVATIONS <br />The Division conducted a monthly monitoring inspection of the site on 3/3/08/ Present <br />during the inspection was Mr. Mark Vanoni of CC&V. <br />The area had received measurable snow the day before which was evident at the time of the <br />inspection. <br />Inspected the Phase I,II,III AND Phase IV LEACH PAD FACILIT AREA. Surface water drainage <br />structures around the facility were found to be in good repair. <br />The following readings were collected from the Phase I,II,III AND IV High and Low Volume <br />Solution collection transducers. <br />Phase I High Volume Solution Collection Transducer # l,read out meter still not <br />functioning,# 2 was recorded at 41.8 and # 3 was at 42.9. Low Volume solution collection <br />transducer $ 1 was recorded at.32 and #2 was at .23. Piezometer for the pond was at 45.0 <br />feet <br />Phase II High Volume Solution Collection transducer # 4 was recorded at34.6 #5 was at 34.9 <br />and # 6 was at 33.3. Low Volume Solution Collection Transducer # 1 was recorded at.16 and <br /># 2 was at .59. Piezometer for the pond was at 34.3. <br />Phase IV High Volume Solution collection Transducer # 7 was recorded at 38.4 # 8 was at <br />36.4 #9 was at 37.7 and # 10 was at 38.2. Low Volume Solution Collection Transducer # 1 <br />was at 11.6 and # 2 was at 14.3 inches of hydrostatic head. <br />Inspected the under drain area. All lower ponds were dry, with the sane amount of snow <br />cover noted through out the permit area, from the recent event. Both the south under drain <br />and AG 1 were discharging at a much lower flow than was noted during the last inspection. <br />Walked to AG 1.5 NPDES discharge point, it was dry. <br />Inspected the External pond, it was holding approximately 18.5 feet of fresh water, water <br />appeared partially frozen at the surface. Low volume solution collection transducer for <br />the pond was recorded at 12.1 for # 1 and 13.5 inches of hydrostatic head for # 2. Note: <br />All hydrostatic head readings are in feet, unless otherwise noted. <br />:,;: <br />Inspected the crusher area, it was active at the time of the inspection, Storm water-` <br />management structures for the area were found to be in good repair. Inspected the main <br />Cresson pit area, it was active at the time of the inspection. Storm water diversion <br />structures for the haul roads were found to be in good repair. CC&V plans to conduct <br />additional maintenance in the area in anticipation of Spring run off. <br />Inspected the Iron Clad/Globe Hill area <br />r.. <br />I & E Contact Address <br />NAME: MR.TIM COMER <br />OPERATOR: CC8.V cc: r CE <br />ADDRESS P.O.BOX 191 <br />CITY/STATE/ZIP: vic-T~R C'C~I ~Ran~ ~io86g r BL <br />r FS, <br />r HW <br />r HMWMD (CH) <br />