Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Climax Mine ACZ Project ID: L60327 <br />.• .. <br />L80327-01 WG218099 Calcium, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Manganese, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Zinc, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />WG218439 Cyanide, total M335.4 -Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />L6032T-02 WG218099 Calcium, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Manganese, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Zinc, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />WG218439 Cyanide, total M335.4 -Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />L80327-03 WG218099 Calcium, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Manganese, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Zinc, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />WG218439 Cyanide, total M335.4 -Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />L80327-04 WG218099 Calcium, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Manganese, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />Zinc, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />WG218439 Cyanide, total M335.4 -Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />REPAD.15.06.05.01 <br />L60327: Page 7 of 11 <br />