Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Climax Mine ACZ Project ID: L57358 <br />.- .. <br />L57358-01 WG208966 Aluminum, total recoverable M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />WG208923 Calcium, dissolved M200.7 ICP M3 The accuracy of the spike recovery does not apply because <br /> analyte concentration in the sample is disproportionate to <br /> the spike level. The recovery of the method control sample <br /> was acceptable. <br />WG208865 Cyanide, total M335.4 - Colorimetric w! M1 Matrix spike recovery was high, the method control sample <br /> distillation recovery was acceptable. <br />WG208735 Nitrogen, ammonia M350.1 -Automated Phenate M2 Matrix spike recovery was low, the method control sample <br /> recovery was acceptable. <br /> M350.1 -Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG209168 Phosphorus, total M365.1 -Auto Ascorbic Acid RA Relative Percent Difference (RPD) was not used for data <br /> (digest) validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG208783 Residue, Non-Filterable (TSS) @105C M160.2 - Gravimetric RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG208946 Sulfate SM4500 SO4-D RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />L57358.02 WG208923 Calcium, dissolved M200.7 ICP <br />WG209092 Chloride M325.2 - Colorimetric <br />WG208905 Cyanide, total M335.4 - Colorimetric w/ <br />distillation <br />L57358-03 WG208923 Calcium, dissolved M200.7 ICP <br />WG209092 Chloride M325.2 - Colorimetric <br />WG208905 Cyanide, total M335.4 - Cobrimetric w/ <br />distillation <br />WG208762 Residue, Filterable (TDS) @180C M160.1 - Gravimetric <br />L57358-04 WG208923 Calcium, dissolved M200.7 ICP <br />WG209092 Chloride M325.2 - Colorimetric <br />WG208905 Cyanide, total M335.4 - Colorimetric w/ <br />distillation <br />WG208762 Residue, Filterable (TDS) @180C M160.1 - Gravimetric <br />M3 The accuracy of the spike recovery does not apply because <br />analyte concentration in the sample is disproportionate to <br />the spike level. The recovery of the method control sample <br />was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too Icw for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the method control sample <br />recovery was acceptable. <br />M3 The accuracy of the spike recovery does not apply because <br />analyte concentration in the sample is disproportionate to <br />the spike level. The recovery of the method control sample <br />was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the method control sample <br />recovery was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M3 The accuracy of the spike recovery does not apply because <br />analyte concentration in the sample is disproportionate to <br />the spike level. The recovery of the method control sample <br />was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the method control sample <br />recovery was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />REPAD.15.06.05.01 <br />L57358: Page 9 of 14 <br />