Laserfiche WebLink
A~Z Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />FMI -Climax Mine Company ACZ Project ID: L66714 <br />~ •- •i ~ ~ s <br /> <br />L6871401 WG238221 Chloride 325.2 / SM450001-E RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br /> WG238048 Cyanide, total M335.4 - Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />L6871402 WG238076 Silver, dissolved M200.8 ICP-MS MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits; the RPD was within the <br /> acceptance limits. <br /> WG238221 Chloride 325.2 / SM45000I-E RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br /> WG238048 Cyanide, total M335.4 - Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />L6871403 WG238076 Silver, dissolved M200.8 ICP-MS MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits; the RPD was within the <br /> acceptance limits. <br /> WG238221 Chloride 325.2 / SM45000I-E RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br /> WG238048 Cyanide, total M335.4 -Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too law for <br /> accurate evaluation (< 10x MDL). <br />L8871404 WG238076 Silver, dissolved M200.8 ICP-MS MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits; the RPD was within the <br /> acceptance limits. <br /> WG238221 Chloride 325.2 / SM45000I-E RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br /> WG238048 Cyanide, total M335.4 -Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br /> distillation validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />REPAD.15.06.05.01 <br />L66714: Page 7 of 11 <br />