Laserfiche WebLink
SENECA II-W <br />Channel PM-2 System <br />HYDROLOGIC INPUT PARAMETERS <br /> SEDCAD 4 <br /> Channel PM-2 <br /> Watershed ID -Structure 6 - SWS1 <br />Watershed Area: <br />1.1 <br />Curve Number: Postmine Conditions <br /> VEGETATION HYDROLOGIC CURVE AREA <br />WATERSHED TYPE COVER SOIL GROUP NUMBER (acres) <br />Reclaimed Good (>70%) C 71 1.1 <br />Total 1.1 <br /> CURVE NUMBER 71 <br /> SEDCAD 4 <br /> Channel PM-2 <br /> Watershed ID -Structure 6 - SWS2 <br />Watershed Area: <br />2.3 <br />Curve Number: Postmine Conditions <br /> VEGETATION HYDROLOGIC CURVE AREA <br />WATERSHED TYPE COVER SOIL GROUP NUMBER (acres) <br />Reclaimed Good (>70%) C 71 1.7 <br />Aspen/Mountain Shrub Good (>70%) B 30 0.6 <br />Total 2.3 <br /> CURVE NUMBER 61 <br />Approved II-W Mine curve numbers are presented in Appendix 13-5B, Postmining Drainage and <br />Sediment Control, Table 1, Seneca II-W (South Expansion Area) Curve Numbers. Values were <br />adapted from Urban Hydrology for Small Watersheds, Technical Release No. 55, Soil Conservation <br />Service, 1986. <br />• <br />• <br />• <br />TR-59 20-1.166 Revised 08/07 <br />