Laserfiche WebLink
• <br />• <br />• <br />TR-59 <br />SENECA II-W <br />Channel PM-2 System <br />HYDROLOGIC INPUT PARAMETERS <br /> SEDCAD 4 <br /> Channel PM-2B <br /> Watershed ID -Structure 3 - SWS1 <br />Watershed Area: <br />33.4 <br />Curve Number: Postmine Conditions <br /> VEGETATION HYDROLOGIC CURVE AREA <br />WATERSHED TYPE COVER SOIL GROUP NUMBER (acres) <br />Reclaimed Good (>70%) C 71 2.68 <br />Aspen/Mountain Shrub Good (>70%) B 30 30.70 <br />Total 33.38 <br /> CURVE NUMBER 33 <br /> SEDCAD 4 <br /> Channel PM-2B <br /> Watershed ID -Structure 3 - SWS2 <br />Watershed Area: <br />23.7 <br />Curve Number: Postmine Conditions <br /> VEGETATION HYDROLOGIC CURVE AREA <br />WATERSHED TYPE COVER SOIL GROUP NUMBER (acres) <br />Reclaimed Good (>70%) C 71 23.65 <br />Total 23.65 <br /> CURVE NUMBER 71 <br />Approved II-W Mine curve numbers are presented in Appendix 13-5B, Postmining Drainage and <br />Sediment Control, Table 1, Seneca II-W (South Expansion Area) Curve Numbers. Values were <br />adapted from Urban Hydrology for Small Watersheds, Technical Release No. 55, Soil Conservation <br />Service, 1986. <br />20-1.163 <br />Revised 05/07 <br />