Laserfiche WebLink
EFCI Southfield Mine -Year 2005 Annual Hydrology Report May 11, 2006 <br />2.0 GROUND WATER INFLOWS, USE AND DISCHARGE <br />2.1 Mine Inflows <br />As previously noted in Section 1.0, quarterly mine inflow monitoring was discontinued after <br />September 2001 because access to monitoring sites was eliminated when the mine portals were <br />sealed in December 2001. Mine inflows for 2001, as the last reporting period, were estimated at 5.2 <br />acre-feet, as presented in Table 1, Mine Water Inflow Summary. The monitoring locations are <br />shown on Figure 1. Prior to 2002, these locations were monitored semi-annually during the spring <br />and fall for each annual reporting period. The 2001 mine inflows represented a decrease from prior <br />yeazs possibly due to continuing drought conditions at that time. Review of historic mine inflow <br />water quality monitoring results from previous Annual Hydrology Reports indicates little variance <br />in inflow water quality over time. <br /> TABLE 1 <br /> MINE WATER INFLOW DATA SUMMARY (from 2001 AHR) <br />Mine Inflow Estimated Monitor Field Data <br />or Seep Mine Area Duration Annual Dates pH Temp. Conduct. <br />(Map I.D. Quantity (M/D/Y) (Units) a <br />I C) <br />lumhos/cm) <br />No.l (Acre-Ftl <br /> Peacock Mine Continuous 1.1 03/21/01 5.1 13.1 3,083 <br />1 seep 09/25/01 5.4 13.2 3,247 <br /> 2 South Shaft Continuous 0.5 03/21/01 8.1 10.5 2,248 <br />2 <br /> 09/25/01 8.4 12.0 1, 902 <br /> 2 South-Last Continuous 1.4 03/21/01 8.1 10.5 2,586 <br />3 Panel seeps 09/25/01 8.3 12.4 2,825 <br /> 1 South Mains Continuous 1.6 03/21/01 8.2 10.8 2,719 <br />4 <br /> seeps 09/25/01 8.3 11.8 2,983 <br /> Moose Panel Jan-May 0.6 03/21/01 6.8 10.3 3,432 <br />5 <br /> seeps <br />Total Estimated Inflow <br />l <br />5.2 Acre-Ft <br />(within accessible areas) <br />Notes from 2001 <br />1. Approx. 1.7 Ac-Ft pumped to the West Mains from combined areas 2 and 4, above. <br />2. Approx. 1.1 Ac-Ft pumped to the 1 North section from area 1, above. <br /> Inflow from areas 3 and 5, above, flows (by gravity) to the West Mains. <br /> 9/01 represents last period mine inflows were monitored prior to sealing mine portals <br />2.2 Mine Water Handling, Use, Consumption and Discharge <br />During active operations, water-handling systems in the mine captured most mine water inflows <br />near their source. Within the mine, captured mine water was pumped to sumps located in Crosscut <br />32 or the 1st North Mains, or flowed by gravity to the mined-out and abandoned west azea of the <br />mine. Water from the Crosscut 32 sump was pumped to the West Mains where it flowed by gravity <br />to the abandoned west area of the mine. Prior to sealing of the mine, mine water handling activities <br />were discontinued. Mine inflows will continue within the sealed mine workings and water will <br />6417/2005 annual hyd rpt.doc N W C C INC. Page 4 <br />