Laserfiche WebLink
2004 0.017 cfs (monthly measurements) <br />2003 0.026 cfs (monthly measurements) <br />2002 0.016 cfs " <br />2001 0.018 cfs " <br />2000 0.024 cfs (from monthly measurements as of 12/99) <br />1999 0.057 cfs (weekly measurements) <br />1998 0.110 cfs " <br />1997 0.033 cfs " <br />1996 0.015 cfs " <br />1995 ~ 0.015 cfs " <br /> <br /> <br />1994 no flow (very low snowpack runoff this year) <br />1993 0.114 cfs (pond was dewatered to repair a leaking <br />dewatering line) <br />This year's average flow value is 97~ of the historic (1993-2006) <br />average flow value, 0.039 cfs. This year, flow was observed only in <br />April and May. Review Of this Site's TDS plot indicates a decreasing <br />trend. Baseline data for this site (WSDB) has been provided in Appendix <br />E1. <br />- Surface Water Site SW-S2W-SGS (WSD5). This site is located on Dry <br />Creek and is the furthest downstream surface water site for this side of <br />Seneca II-W. Monitoring at this site began in March 1983. The TDS plot <br />indicates an increasing trend. The peak TDS value occurred in September <br />2003. The Seneca II-W PHC, Table 17-42b, predicts and average irrigation <br />season (June-September) TDS value of 2451 mg/1 at this site, while a <br />value of 1645 mg/1 was observed this year. <br />Sage Creek <br />- NPDES 015 (NPDESIS). This site is located on the southern Sage Creek <br />tributary in the II-W South area. It is monitored weekly except when <br />inaccessible by truck. Pond 015 was completed in late August 1999 and <br />began to discharge in February 2000. Average flow for each water year <br />was: <br />2006 0.054 cfs <br />2005 0.027 cfs <br />l7 <br />