Laserfiche WebLink
PART I <br />Page 4 of 19 <br />• <br />C. FOOTPIOTES <br />1/ - when the most sensitive analytical method which complies with Part <br />I.F.2, of the permit has a detection limit greatE:r than or equal to <br />the permit limit, the permittee shall report "less than the <br />detectable limit", as appropriate. Such reports shall not be <br />considered as violations of the permit limit. <br />The present lowest method detection limit for specific parameters <br />(which have limitations which are, is some cases,. less than or equal <br />[o Lhe detection limit) are as follows: <br />Total Residual Chlorine 0.05 mg/1 <br />Total Recoverable Cadmium 0.0003 mg/1 <br />Total Recoverable Capper 0.005 mg/1 <br />Total Recoverable Lead 0.005 mg/1 <br />Total Mercury 0.00025 mg/1 <br />Total Recoverable Nickel 0.05 mg/1 <br />Total Recoverable Silver 0.0002 mg/1 <br />Total Recoverable Ziac 0.05 mg/1 <br />m/ - Fecal conform bacteria average concentrations shall be determined by <br />the geometric mean of all samples collected during a thirty (30) • <br />consecutive day period. The 7 day average shall be determined by the <br />geometric mean of all samples taken during a seven (7) day period. <br />Code: i - 17 Date: 9-84, revised 10-86, revised 06-87, revised 12-87, <br />revised ].2-88 <br />• <br />