REP39389
DRMS
>
Back File Migration
>
Report
>
REP39389
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 12:25:52 AM
Creation date
11/27/2007 8:23:03 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981014
IBM Index Class Name
Report
Doc Date
1/26/1994
Doc Name
SEMI ANNUAL SUBSIDENCE MONITORING REPORT
Permit Index Doc Type
SUBSIDENCE REPORT
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2) Structures <br />Monitored structures include the three Thompson Ranch <br />buildings, Newlin Creek stream channel, and Florence City water <br />line. quarterly monitoring detects ground movement that potentially <br />results from mining. Summarized monitoring data for the above <br />structures are presented on Table 2, Florence Water Line, and Table <br />3, Thompson Ranch Structures and Newlin Creek Point. <br />A review of the monitoring data for the Ranch Structures 'and <br />Newlin Creek Point show that no subsidence is occurring at the <br />monitored points. Accordingly, mining is not been active in the <br />vicinity of these structures since Energy Fuels acquired the <br />project in 1985. <br />Monuments along the Florence Water Line similarly show no <br />measurable subsidence except in those areas where retreat mining <br />has been completed. Those monuments showing potential subsidence <br />effects are Monuments D and E located on the west end of the mine <br />development. Of these, only Monument D is indicating minor <br />subsidence effects during the reporting period. Monument E exhibits <br />the greatest cumulative subsidence; 1.55 feet through the reporting <br />period. This value is approximately 56 percent of the maximum 2.79 <br />feet as predicted in the permit application. There is no indication <br />that the measured subsidence has adversely effected operation of <br />the Florence Water Line. ' <br />Structure monitoring indicates that none or only minor <br />subsidence has occurred at the monitored locations. Measured <br />subsidence through the reporting period is within predicted limits <br />presented in the permit application. Only minor additional <br />subsidence is expected to happen at the monitored structures.i <br />